HP ProLiant DL380 Generation 6
Компания Sever Unit представляет полное описание HP ProLiant DL380 Generation 6. В мануале вы найдете подробные технические характеристики HP ProLiant DL380 Generation 6, а также дополнительные опции для HP ProLiant DL380 Generation 6. По вопросам приобретения HP ProLiant DL380 Generation 6 обращайтесь в компанию Server Unit по тел.: +7 (495) 665-65-25, market@server-unit.ru|
Содержание технического описания HP ProLiant DL380 Generation 6 |
Overview
|
HP ProLiant DL380 Generation 6 (G6) | |||
|
| ![]() | ||
| Front View: | Rear View: | ||
| 1. | Quick removal access panel | 1. | PCI slot 5 |
| 2. | Intel Quad-Core Processor (Performance models include two processors) | 2. | PCI slot 6 |
| 3. | PCI slot 4 | ||
| 3. | Second Intel Quad-Core Processor | 4. | PCI slot 2 |
| 4. | Eighteen slots: DDR3 Registered (RDIMM) or Unbuffered (UDIMM) memory | 5. | PCI slot 3 |
| 6. | PCI slot 1 | ||
| 7. | Power supply 2 | ||
| 5. | Hot-plug fans, full N+1 redundancy | 8. | Power supply 1 |
| 6. | Slim Optical Bay (SATA DVD-RW Optical Drive included on Performance models) | 9. | USB connectors (2) |
| 10. | Video connector | ||
| 7. | UID LED button | 11. | NIC 1 connector |
| 8. | Health LED | 12. | NIC 2 connector |
| 9. | Power On/Standby button and system power LED | 13. | Mouse connector |
| 10. | USB connectors (2) | 14. | Keyboard connector |
| 11. | Video connector | 15. | Serial connector |
| 12. | Systems Insight Display | 16. | iLO2 connector |
| 17. | NIC 3 connector | ||
| 18. | NIC 4 connector | ||
| | |||
| At A Glance |
|
The HP ProLiant DL380 G6 Server continues to deliver on its heritage of engineering excellence with increased flexibility and performance, enterprise-class uptime and manageability, 2-socket Intel Xeon performance, and 2U density for a variety of applications.
|
|
Содержание технического описания HP ProLiant DL380 Generation 6 |
Standard Features
| NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section. | |
| Processor One of the following depending on Model | Quad-Core Processors |
| Intel® Xeon® Processor X5570 (2.93 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) | |
| Intel® Xeon® Processor X5560 (2.80 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) | |
| Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) | |
| Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) | |
| Intel® Xeon® Processor E5530 (2.40 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) | |
| Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) | |
| Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80W, DDR3-800) | |
| Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800) | |
| Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2) | |
| Intel® Xeon® Processor L5506 (2.13 GHz, 4MB L3 Cache, 60W, DDR3-800) | |
| Dual-Core Processors | |
| Intel® Xeon® Processor E5502 (1.86 GHz, 4MB L3 Cache, 80W, DDR3-800) | |
| NOTE: HT indicates
that the processor model supports Intel® Hyper-Threading Technology. NOTE: Turbo indicates the maximum potential frequency increment when using Intel® Turbo Boost Technology, with 4, 3, 2, and 1 cores active. NOTE: DDR3 speed is the maximum memory speed of the processor. Actual memory speed may depend on the quantity and type of DIMMs installed. NOTE: For the Intel 5500 Series, the letter preceding the model number indicates the performance/wattage of the processor. "X" denotes High Performance/Wattage; "E" denotes Enterprise Performance/Wattage (Mainstream); and "L" denotes Lower Wattage. NOTE: Up to 2 processors supported. Performance configurations include two processors. Mixing different processor models is not supported. | |
| | |
| Cache
Memory One of the following depending on Model | 8MB
(1 x 8MB) Level 3 cache NOTE: All processor models except for those identified below. |
| 4MB
(1 x 4MB) Level 3 cache NOTE: For processors E5506/L5506/E5504/E5502. | |
|
| |
| Chipset | Intel® 5520 Chipset NOTE: For more information regarding Intel chipsets, please see the following URL: http://www.intel.com/products/server/chipsets/. |
|
|
|
| Upgradeability | Upgradeable to 2 processors (8 cores) |
|
|
|
| Memory Protection | Advanced ECC (multi-bit error protection) |
| Mirroring mode | |
| Lockstep mode | |
| | |
| Memory | Type | DDR3 Registered (RDIMM) and Unbuffered (UDIMM) |
| Standard (Performance Models) | 12 GB (6 x 2 GB) PC3-10600R (DDR3-1333) Registered DIMMs | |
| Standard (Base Models) | 6 GB (3 x 2 GB) PC3-10600R (DDR3-1333) Registered DIMMs | |
| Standard (Entry Models) | 4 GB (2 x 2 GB) PC3-10600R (DDR3-1333) Registered DIMMs | |
| Standard (High Efficiency Models) | 4 GB (2 x 2 GB) PC3-10600E (DDR3-1333) Unbuffered DIMMs | |
| Maximum (RDIMM) | 144 GB (18 x 8 GB) for Registered Memory configurations | |
| Maximum (UDIMM) | 24 GB (12 x 2 GB) for Unbuffered Memory configurations | |
| NOTE:
If only one processor is installed, only half the DIMM slots are available NOTE: Depending on the memory configuration and processor model, the memory speed may run at 1333MHz, 1066MHz, or 800MHz. Please see the Online Memory Configuration Tool at: www.hp.com/go/ddr3memory-configurator. | ||
DDR3
memory options part number decoder | ||
![]() | ||
| | ||
| Network Controller | Two HP NC382i Dual Port Multifunction Gigabit Server Adapters (four ports total) with TCP/IP Offload Engine, including support for Accelerated iSCSI |
|
|
|
| Expansion Slots
NOTE: The system board has 2 PCI connectors, but the below riser cards have the actual PCI slots, to which PCI cards attach. |
|||||||
| Primary
Riser (Standard) |
Expansion Slots # |
Technology |
Bus Width** |
Connector Width |
Bus Number* |
Form Factor |
Notes |
|
1 |
PCIe Gen2
|
X8 |
X16 |
7 |
Full Length, Full Height Slot
| ||
| 2 | PCIe Gen2 | X4 | X8 | 10 | Half Length, Full Height Slot | ||
| 3 |
PCIe Gen2
|
X4 |
X8 |
13 |
Half Length, Full Height Slot | ||
| *
Default bus assignment (in decimal). Inserting cards with PCI bridges may alter
the actual bus assignment number ** Indicates the number of physical electrical lanes running to the connector. | |||||||
| PCIe
Riser (Optional Secondary) |
Expansion Slots # |
Technology |
Bus Width** |
Connector Width |
Bus Number* |
Form Factor |
Notes |
| 4 | PCIe Gen2 | X8 | X16 | 16 | Full length, full height slot | ||
| 5 | PCIe Gen2 | X4 | X8 | 20 | Half length, half height slot | ||
| 6 | PCIe Gen2 | X4 | X8 | 23 | Half length, half height slot | ||
| *
Default bus assignment (in decimal). Inserting cards with PCI bridges may alter
the actual bus assignment number ** Indicates the number of physical electrical lanes running to the connector. | |||||||
| PCIe/PCI-X Riser (Optional Primary) |
Expansion Slots # |
Technology |
Bus Width** |
Connector Width |
Bus Number* |
Form Factor |
Notes |
| 1 | PCI-X (133MHz, 3.3 Volt) | 64-bit | N/A | 7 | Full length, half height slot | ||
| 2 | PCI-E Gen2 | X8 | X16 | 11 | Half Length, Full Height | ||
| 3 | PCI-E Gen2 | X4 | X8 | 15 | Half Length, Full Height | ||
| *
Default bus assignment (in decimal). Inserting cards with PCI bridges may alter
the actual bus assignment number ** Indicates the number of physical electrical lanes running to the connector. | |||||||
| PCIe/PCI-X Riser (Optional Secondary) |
Expansion Slots # |
Technology |
Bus Width** |
Connector Width |
Bus Number* |
Form Factor |
Notes |
| 4 | PCI-X (133MHz, 3.3 Volt) | 64-bit | Not applicable | 19 | Full length, Full height slot | ||
| 5 | PCI-E Gen2 | X8 | X16 | 23 | Low Profile slot | ||
| 6 | PCI-E Gen2 | X4 | X8 | 27 | Low Profile slot | ||
| *
Default bus assignment (in decimal). Inserting cards with PCI bridges may alter
the actual bus assignment number ** Indicates the number of physical electrical lanes running to the connector. | |||||||
| x16
PCIe Riser (Optional Primary) |
Expansion Slots # |
Technology |
Bus Width** |
Connector Width |
Bus Number* |
Form Factor |
Notes |
| 1 | PCIe Gen2 | x16 | x16 | 13 | Full Length, Full Height slot | Supports up to 225W; single wide cards only | |
| *
Default bus assignment (in decimal). Inserting cards with PCI bridges may alter
the actual bus assignment number ** Indicates the number of physical electrical lanes running to the connector. | |||||||
| x16
PCIe Riser (Optional Secondary) |
Expansion Slots # |
Technology |
Bus Width** |
Connector Width |
Bus Number* |
Form Factor |
Notes |
| 4 | PCIe Gen2 | x16 | x16 | 16 | Full Length, Full Height slot | Supports up to 225W; single wide cards only | |
| *
Default bus assignment (in decimal). Inserting cards with PCI bridges may alter
the actual bus assignment number ** Indicates the number of physical electrical lanes running to the connector. | |||||||
|
| |||||||
| Storage
Controller One of the following depending on Model | Entry Models | HP Smart Array P410i/Zero Memory Controller (RAID 0/1/1+0) |
| Base Models | HP Smart Array P410i/256 MB Controller (RAID 0/1/1+0/5/5+0) | |
| Performance Models | HP Smart Array P410i/512 MB BBWC Controller (RAID 0/1/1+0/5/5+0/6) | |
| High Efficiency Models | HP Smart Array P410i/Zero Memory Controller (RAID 0/1/1+0) | |
| Available upgrades: 256MB, 512MB with BBWC, Battery kit upgrade (for BBWC), and Smart Array Advanced Pack (SAAP). | ||
| | ||
| Storage | Diskette Drive | None Standard |
| Optical Drive One of the following depending on Model |
None Standard on Entry, High Efficiency, and Base Models | |
| HP Slim SATA DVD RW Optical Drive Standard on Performance Models | ||
| Hard Drives | None Standard | |
|
|
||
| Maximum Internal Storage | Hot Plug SFF SAS | 4.80TB | 16 x 300GB |
| Hot Plug LFF SAS | 6.0TB | 6 x 1TB | |
| | |||
| Interfaces | Serial | 1 |
| Pointing Device (Mouse) | 1 | |
| Graphics | 1 | |
| Keyboard | 1 | |
| VGA | 2 (1 front, 1 back) | |
| Network RJ-45 | 2 | |
| iLO remote management port | 1 | |
| SD slot | 1 | |
| USB 2.0 Ports | 5 total: 2 front, 2 back, 1
internal NOTE: Please see the following URL for additional information regarding USB support: http://h18004.www1.hp.com/products/servers/platforms/usb-support.html. |
|
|
|
||
| Graphics |
Integrated ATI ES1000, 32MB video standard
NOTE: Maximum resolution available via iLO 2 remote console is 1280 x 1024. |
|
|
|
| Form Factor | Rack (2U); Height 3.38-inch (8.59 cm); Width: 17.25 (44.54 cm); Depth: 27.25 inches (69.98 cm) |
|
|
|
| HP Insight Control Suite |
HP Insight Control suite delivers essential management, including proactive
health management, lights out remote control, optimization of power usage,
rapid server deployment, performance analysis, vulnerability scanning
and patch management and virtual machine management.
Additional Insight Software standalone products and management tools included on the Insight Software media kit can be installed manually:
NOTE: HP Insight Server Migration
software for ProLiant can be installed from the SMP CD included in the
Insight Software media kit. |
| | |
| HP ProLiant Onboard Administrator |
HP ProLiant Onboard Administrator (powered by the Integrated Lights-Out 2 management
processor) simplifies server setup, health monitoring, power and thermal control,
and lights-out remote administration of ProLiant ML, DL, and BL servers. HP ProLiant
Onboard Administrator functions without additional software, and can be accessed
from any location via a web browser. It works hand-in-hand with HP Systems Insight
Manager, Insight Control, and Insight Dynamics - VSE suite helping customers unlock
the value of the ProLiant platform and deliver the highest possible quality of
IT service to the business.
Unlock the full remote administration capabilities of HP ProLiant Onboard Administrator with Integrated Lights-Out 2 Advanced. |
|
| |
| Server Management Stand Alone Software Products | HP Systems Insight Manager | HP Systems Insight Manager (HP
SIM) provides a unified, secure and extensible standards-based environment
to centrally manage servers, storage and other infrastructure devices, (both
HP and non-HP) across multiple operating system platforms. For additional information, please see: www.hp.com/go/insight |
| HP Insight Rapid Deployment software | HP Insight Rapid Deployment Software (RDP) extends HP Systems Insight Manager with a complete deployment solution for HP ProLiant servers. RDP provides a central location to configure server hardware, deploy Windows, Linux and VMware ESX operating environments and install HP ProLiant Support Pack drivers using images and scripted profiles. For more information, visit: http://www.hp.com/go/rdp. | |
| HP Insight Server Migration software for ProLiant |
Upgrading, replacing, or virtualizing your existing server? Effortlessly transition to new virtual or physical HP ProLiant servers or BladeSystem with automated, accurate and affordable migration of OS, application and data. HP Insight Server Migration software for ProLiant automates the manual processes required for migrating servers between physical or virtual platforms, whether migrating to VMware or Microsoft or Citrix virtual machines. SMP allows all of the following migrations:
NOTE: For more information, visit: http://www.hp.com/go/migrate. |
|
| HP Insight Dynamics - VSE suite for ProLiant | The HP Insight Dynamics - VSE
suite for ProLiant is advanced infrastructure management software that allows
you to analyze and optimize your adaptive infrastructure to manage physical
and virtual resources in the same way. HP Insight Dynamics - VSE gives you
a powerful toolkit to accelerate complex technology projects and simplify
daily operations. It enables you to plan capacity and power continuously,
balance across physical and virtual resources, ensure cost-effective high
availability and provision infrastructure consistently. HP Insight Orchestration, an optional extension to Insight Dynamics - VSE, enables IT organizations to provision infrastructure consistently and automatically from pools of shared resources using a self-service portal. Resources provisioned can range from a single virtual machine to complex multi-tier environments and their associated physical and virtual resource requirements. HP Insight Recovery, also an optional extension for Insight Dynamics - VSE, enables cost-effective disaster recovery for physical and virtual environments. Application environments can be reactivated in minutes with the touch of a button to a remote location. NOTE: For more information, visit: http://www.hp.com/go/insightdynamics, http://www.hp.com/go/insightorchestration, http://www.hp.com/go/insightrecovery |
|
| HP Integrated Lights-Out (iLO) Advanced Pack | Unlocks the full capabilities of the ProLiant Onboard Administrator with comprehensive remote control including Virtual KVM remote graphical console, power management capabilities such as power measurement, regulation, and capping, new iLO Text Console, automatic and on-demand video recording of server events, global team collaboration for up to four remote users, virtual media (floppy, CD/DVD, USB key), virtual folders, and enterprise security (directory services and two-factor authentication). For additional information, please see: www.hp.com/go/iLO | |
| HP Insight Power Manager software (IPM) | Upgrades the single-server remote management capabilities of iLO Select/Advanced to include centralized reporting and policy-based management of power consumption and thermal output provided by the Insight Power Manager. IPM unifies all of this functionality within a single user interface - HP Systems Insight Manager. For additional information, please see: www.hp.com/go/ipm | |
| NOTE: Flexible and volume quantity license kits are available for Insight Software products. Refer to: http://www.hp.com/servers/proliantessentials or the various Insight Software product QuickSpecs for more information. | ||
|
|
||
| Core Infrastructure Management | HP Foundation Pack |
Managing the growing number of servers can be complex and expensive for your
organization. IT managers need to address changing business needs with tools that
meet the challenges of managing today's complex Datacenters.
SmartStart version supported (minimum):
SmartStart 8.20 |
| Insight Management Providers (WBEM) | The HP Insight Management
WBEM Providers leverage the rich set of base-level instrumentation provided by
the system management controllers and drivers, I/O controllers and drivers, and
system firmware interfaces delivering in-depth hardware management, including
hardware inventory data, system state, and event notifications.
The
Insight Management Providers are included on ProLiant Support Packs. | |
| Insight Management Agents (SNMP) | The Insight Management
Agents should be installed on all HP servers to present system instrumentation,
health and configuration information into HP Systems Insight Manager and the HP
System Management Homepage. The HP System Management Homepage aggregates systems
data from Insight Management Agents and other HP management tools, providing a
consolidated browser-based interface for managing individual servers. Insight Management Agents and The HP System Management Homepage are included on ProLiant Support Packs, and can also be installed using the server profiles provided with the HP Insight Rapid Deployment software. For additional information about the Management Agents and the HP System Management Homepage please visit the management Web site at: http://www.hp.com/servers/manage. | |
| Subscriber's Choice | Subscriber's
Choice Driver and Support Alerts/Notifications is a web-based email subscription
service that provides software and driver change notifications for ProLiant products.
Sign up at: http://www.hp.com/go/subscriberschoice and customize your profile to receive various new alerts as they become available, on a weekly or monthly basis. | |
| ProLiant Support Packs and ROMPaq, software | The latest software, drivers, and firmware fully optimized and tested for your ProLiant server and options, available through ProLiant Support Packs the HP Insight Rapid Deployment Software, SmartStart or downloaded from software and drivers download pages website at: http://www.hp.com/go/support. | |
| | ||
| HP Serviceguard for Linux (SGLX) |
HP Serviceguard for Linux provides high availability clustering for Linux
applications running on HP Integrity, HP ProLiant and other supported
industry-standard servers. Serviceguard for Linux reduces planned and
unplanned downtime and delivers efficient, continuous access to business-critical
applications - with all of the enterprise features you expect from HP.
NOTE: For additional information including
software and server support on HP Serviceguard for Linux, visit: http://www.hp.com/go/sglx
or see the HP Serviceguard for Linux QuickSpecs. |
| | |
| Industry Standard Compliance | ACPI 2.0 Compliant PCI 2.2 Compliant WOL Support Microsoft® Logo certifications USB 2.0 Support |
| | |
| Security | Power-on password Keyboard password Diskette drive control Diskette boot control QuickLock, Network Server Mode Parallel and serial interface control Administrator's password |
|
|
|
| Security - Trusted Platform Module | Trusted
Platform Module option kit The TPM (Trusted Platform Module) is a microcontroller chip that can securely store artifacts used to authenticate the server platform. These artifacts can include passwords, certificates and encryption keys. Windows® BitLocker™ Drive Encryption (BitLocker) is a data protection feature available in Windows Server® 2008. BitLocker leverages the enhanced security capabilities of a Trusted Platform Module (TPM) version 1.2. The TPM works with BitLocker to help protect user data and to ensure that a server running Windows Server 2008 has not been tampered with while the system was offline. For more information about TPM, including a white paper, go to www.hp.com/go/TPM NOTE: ProLiant OS pre-installed units will come with the partition required for TPM deployment. NOTE: The TPM key is unique to every TPM deployed server and must be retained. Misplacing or losing the key could result in data loss. |
|
| |
| Server Power Cords | High voltage power
cord ships standard with all part numbers. NOTE: HP ProLiant DL servers no longer ship standard with a 12-foot NEMA 5-15P to C13 power cords (227099-001) that allow connection to 110V US wall outlets in a home or office. ProLiant DL servers are primarily connected to PDU's in data center racks so they now ship standard with only a PDU 6-foot C-14 to C13 power cord (142258-001). If a user wishes to power a ProLiant DL server using a110V receptacle (NEMA-15), the 12-foot NEMA 5-15 to C13 power cord (227099-001) must be ordered separately. Also available: 110 volt 6-Foot NEMA 5-15p to C13 (AF556A). |
| | |
| UPS and PDU Power Cord Matrix |
Please see the UPS and PDU cable
matrix that lists cable descriptions, requirements, and specifications for
UPS and PDU units: http://h18004.www1.hp.com/products/servers/proliantstorage/power-protection/index.html |
| | |
| Power Supply | HP has a new design for ProLiant power. The new Common Slot Power Supply bay. This design provides the customer with commonality in power supplies across multiple platforms to save on the cost of spares and allows HP to offer multiple power solutions to fit the customers' needs. Many HP ProLiant Servers come with Common Slot, High Efficiency and Right-Size Power Supplies. Common Slot (CS) designates commonality of the power supply across multiple ProLiant servers. HP's new Common Slot power supplies are designed for highest efficiency to provide power efficiency without degrading performance of the ProLiant. Power Supplies will have efficiency ratings up to 92%. There are three Right Size power options available, depending on the configuration of your server. To make sure you select the correct power supply to meet your configuration, we suggest that you use the HP Power Advisor to decide the "Right-Size" for your configuration. All HP Common Slot power sources are UL, CE Mark Compliant, Hot Plug and Redundant. |
| | |
| Common Slot ProLiant | It is highly recommended that you use the HP Power Advisor in defining the "Right-Size" power supply for your needs. HP offers four Power Supply Options:
HP's ProLiant Common Slot Power supplies (460W
& 750W) meet multiple Energy Efficiency Initiatives. Climate Savers Computing
Initiative GOLD, ECOS Consulting 80PLUS GOLD and plans on offering models that
meet the Energy Star for Server requirements when they are published. |
|
| |
| System Fans | Fully redundant hot plug fans
ship standard (N+1). NOTE: One processor models include four fans. Two processor models include six fans. |
|
|
|
| Operating Systems and Virtualization Software Support for ProLiant Servers |
Microsoft
Windows Server |
|
|
|
| Rack Airflow Requirements |
Rack 10000 series Cabinets
CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage. |
| NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the server, or to the server documentation located in the Support section at the following URL: www.hp.com/servers/dl380. | |
|
|
|
| Rack Kit |
The HP ProLiant DL380 quick deploy rail system provides tool-free support
for racks with square or round mounting holes (including Compaq/HP 7000*,
9000, 10000 and HP series), with an adjustment range of 24" - 36".
The ambidextrous cable management arm can be mounted on either the left
or right side for improved cable management. |
|
| |
| Telco Rack Support |
DL380 Telco Rack Kit: |
|
|
|
| Factory Express Portfolio for Servers and Storage |
HP Factory Express offers configuration, customization, integration and deployment
services for HP servers and storage products. Customers can choose how their factory
solutions are built, tested, integrated, shipped and deployed. |
| | |
| HP Enterprise Configurator | The HP eConfigure-Enterprise Configurator now provides factory default racking for our HP hardware portfolio. This approach is aligned with our strategic direction to meet the needs and expectations of our valued customers. If you require "custom" rack configuration, please contact HP's Customer Business Center or an Authorized Partner for assistance. http://www.hp.com/products/configurator. |
| | |
| Service and Support |
HP Care Pack services include coverage for the HP branded hardware options
qualified for the server and purchased at the same time or afterward that
are internal to the enclosure. This also includes the 22" and smaller
external monitors and tower UPS options up to 3kVA. These items will be
covered at the same service level and for the same coverage period as
the server. Coverage of UPS Battery is not included, and standard warranty
terms & conditions apply. For servers or storage systems installed
within a rack, service also covers all HP qualified rack options installed
within the same rack.
Enhanced Service - optimize service level to increase IT performance and availability.
Refer to the information on "Installation & Start-Up" for
service on ProLiant server and Microsoft or Linux O/S per the Customer
Description and/or Data Sheet; to be delivered on a scheduled basis 8am-5pm,
M-F, excluding HP holidays. |
|
Содержание технического описания HP ProLiant DL380 Generation 6 |
HPC Interconnects
| NOTE: High Performance Computing (HPC) interconnect technologies are available for the DL380 under the Cluster Platform product portfolio. These high-speed interconnects are fully supported by HP when they are part of these configure to order clusters. Solutions can be defined with a lot of flexibility with the help of configuration tools. Please visit the following URL to configure HPC Clusters with InfiniBand, Gigabit Ethernet or Myrinet Interconnects: http://www.hp.com/techservers/clusters/ucp/index.html |
|
|
| HPC Interconnect | InfiniBand | PCI-X and PCI-Express adapters |
| Gigabit Ethernet | Use embedded ports | |
| Myrinet XP | PCI-X Rev D and Rev E adapters |
|
Содержание технического описания HP ProLiant DL380 Generation 6 |
Models
|
NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section. | ||
|
HP DL380 G6 Performance Models | Processor(s) Two of the following depending on Model | (2)
Intel® Xeon® Processor X5560 (2.80 GHz, 8MB L3 Cache, 95W, DDR3-1333,
HT, Turbo 2/2/3/3) (2) Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) |
| Cache Memory | 8MB (1 x 8MB) Level 3 cache | |
| Memory | 12 GB (6 x 2 GB) PC3-10600R (DDR3-1333) Registered DIMMs | |
| Network Controller | Two HP NC382i Dual Port Multifunction Gigabit Server Adapters | |
| Storage Controller | HP Smart Array P410i/512MB with BBWC | |
| Hard Drive | None ship standard | |
| Internal Storage | Standard: 8 SFF SAS/SATA
HDD Bays Optional: 16 SFF SAS/SATA HDD Bays | |
| Optical Drive | HP Slim SATA DVD RW drive | |
| Power Supply | (2) 750W Hot Plug Power Supplies | |
| Fans | (6) (N+1 redundancy standard) | |
| Form Factor | Rack (2U), Height 3.38-inch (8.59 cm); Width: 17.25 (44.54 cm); Depth: 27.25 inches (69.98 cm) | |
| | ||
|
HP DL380 G6 Performance Models with ICE standard | Processor(s) Two of the following depending on Model | (2)
Intel® Xeon® Processor X5560 (2.80 GHz, 8MB L3 Cache, 95W, DDR3-1333,
HT, Turbo 2/2/3/3) (2) Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) |
| Cache Memory | 8MB (1 x 8MB) Level 3 cache | |
| Memory | 12 GB (6 x 2 GB) PC3-10600R (DDR3-1333) Registered DIMMs | |
| Network Controller | Two HP NC382i Dual Port Multifunction Gigabit Server Adapters | |
| Storage Controller | HP Smart Array P410i/512MB with BBWC | |
| Hard Drive | None ship standard | |
| Internal Storage | Standard: 8 SFF SAS/SATA
HDD Bays Optional: 16 SFF SAS/SATA HDD Bays | |
| Optical Drive | HP Slim SATA DVD RW drive | |
| Power Supply | (2) 750W Hot Plug Power Supplies | |
| Fans | (6) (N+1 redundancy standard) | |
| Insight Control Environment (ICE) | ICE 24x7 support | |
| Form Factor | Rack (2U), Height 3.38-inch (8.59 cm); Width: 17.25 (44.54 cm); Depth: 27.25 inches (69.98 cm) | |
| | ||
|
HP DL380 G6 Base Models | Processor(s) One of the following depending on Model | (1)
Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066,
HT, Turbo 1/1/2/2) (1) Intel® Xeon® Processor E5530 (2.40 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) (1) Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) |
| Cache Memory | 8MB (1 x 8MB) Level 3 cache | |
| Memory | 6 GB (3 x 2 GB) PC3-10600R (DDR3-1333) Registered DIMMs | |
| Network Controller | Two HP NC382i Dual Port Multifunction Gigabit Server Adapters | |
| Storage Controller | HP Smart Array P410i/256MB Controller | |
| Hard Drive | None ship standard | |
| Internal Storage | Standard: 8 SFF SAS/SATA
HDD Bays Optional: 16 SFF SAS/SATA HDD Bays | |
| Optical Drive | None ship standard | |
| Power Supply | (1) 460W Hot Plug Power Supply | |
| Fans | (4) (N+1 redundancy standard) | |
| Form Factor | Rack (2U), Height 3.38-inch (8.59 cm); Width: 17.25 (44.54 cm); Depth: 27.25 inches (69.98 cm) | |
| | ||
|
HP DL380 G6 High Efficiency Models | Processor(s) | (1) Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2) |
| Cache Memory | 8MB (1 x 8MB) Level 3 cache | |
| Memory | 4 GB (2 x 2 GB) PC3-10600E (DDR3-1333) Unbuffered DIMMs | |
| Network Controller | Two HP NC382i Dual Port Multifunction Gigabit Server Adapters | |
| Storage Controller | HP Smart Array P410i/Zero Memory Controller | |
| Hard Drive | None ship standard | |
| Internal Storage | Standard:
8 SFF SAS/SATA HDD Bays Optional: 16 SFF SAS/SATA HDD Bays | |
| Optical Drive | None ship standard | |
| Power Supply | (1) 460W Hot Plug Power Supply | |
| Fans | (4) (N+1 redundancy standard) | |
| Form Factor | Rack (2U), Height 3.38-inch (8.59 cm); Width: 17.25 (44.54 cm); Depth: 27.25 inches (69.98 cm) | |
| | ||
|
HP DL380 G6 Entry Models | Processor(s) | (1) Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800) |
| Cache Memory | 4MB (1 x 4MB) Level 3 cache | |
| Memory | 4 GB (2 x 2 GB) PC3-10600R (DDR3-1333) Registered DIMMs | |
| Network Controller | Two HP NC382i Dual Port Multifunction Gigabit Server Adapters | |
| Storage Controller | HP Smart Array P410i/Zero Memory Controller | |
| Hard Drive | None ship standard | |
| Internal Storage | Standard:
8 SFF SAS/SATA HDD Bays Optional: 16 SFF SAS/SATA HDD Bays | |
| Optical Drive | None ship standard | |
| Power Supply | (1) 460W Hot Plug Power Supply | |
| Fans | (4) (N+1 redundancy standard) | |
| Form Factor | Rack (2U), Height 3.38-inch (8.59 cm); Width: 17.25 (44.54 cm); Depth: 27.25 inches (69.98 cm) | |
| | ||
| Country Code Key | XX=00 | U.S. |
| XX=20 | Brazil | |
| XX=29 | Japan | |
| XX=37 | APD | |
| XX=42 | Euro | |
| XX=AA | PRC |
|
Содержание технического описания HP ProLiant DL380 Generation 6 |
Configuration Information - Factory Integrated Models
|
NOTE: This section lists some of the steps required to configure a Factory
Integrated Model. To ensure only valid configurations are ordered, HP recommends
the use of an HP approved configurator. Contact your local sales representative
for information on CTO product offerings and requirements. | |||
| Step 1: Base Configuration (choose one of the following configurable models) | |||
| Models | HP DL380R06 CTO Chassis |
494329-B21 | |
| Factory Integrated Model ships with: | |||
| Two HP NC382i
Dual Port Multifunction Gigabit Server Adapters
System Fans - 4 (2 additional fans
included with second processor) | |||
| HP DL380R06 LFF CTO Chassis | 516919-B21 | ||
| Factory Integrated Model ships with: | |||
| Two HP NC382i
Dual Port Multifunction Gigabit Server Adapters
Drive Cage - 6-LFF | |||
| | |||
| Step 2: Choose Required Options (only one of the following from each list unless otherwise noted) | ||
| Processors | Quad-Core Processors | |
| Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800), FIO | 492136-L21 | |
| Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80W, DDR3-800), FIO |
492131-L21
|
|
| Intel® Xeon® Processor L5506 (2.13 GHz, 4MB L3 Cache, 60W, DDR3-800), FIO |
500089-L21
|
|
| Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2), FIO |
492239-L21
|
|
| Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2), FIO |
500087-L21
|
|
| Intel® Xeon® Processor E5530 (2.40 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2), FIO |
492237-L21
|
|
| Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2), FIO | 492244-L21 | |
| Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3), FIO |
492234-L21
|
|
| Intel® Xeon® Processor X5560 (2.80 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3), FIO | 492232-L21 | |
| Intel® Xeon® Processor X5570 (2.93 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3), FIO |
500094-L21
|
|
| Dual-Core Processors | ||
| Intel® Xeon® Processor E5502 (1.86 GHz, 4MB L3 Cache, 80W, DDR3-800), FIO | 500085-L21 | |
| Base Memory | Registered DIMMs (RDIMMs) | |
| HP 2GB 2Rx8 PC3-10600R-9 Kit |
500656-B21
|
|
| HP 4GB 2Rx4 PC3-10600R-9 Kit |
500658-B21
|
|
| HP 4GB 4Rx8 PC3-8500R-7 LP Kit |
500660-B21
|
|
| HP 8GB 2Rx4 PC3-8500R-7 Kit |
516423-B21
|
|
| HP 8GB 2Rx4 PC3-10600R-9 Kit | 500662-B21 | |
| Unbuffered with ECC DIMMs (UDIMMs) | ||
| HP 1GB 1Rx8 PC3-10600E-9 Kit | 500668-B21 | |
| HP 2GB 2Rx8 PC3-10600E-9 Kit | 500670-B21 | |
| NOTE:
All DDR3 memory option kits consist of one DIMM per kit. For detailed memory
configuration rules and guidelines, please use the Online DDR3 Memory Configuration
Tool: www.hp.com/go/ddr3memory-configurator. NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient. |
||
| Power Supplies | NOTE: Refer to HP Power Advisor when selecting a power supply for your configuration, www.hp.co/go/hppoweradvisor. Many HP ProLiant Servers now offer new power options, including Common Slot Power Supplies. These power supplies come in multiple power ratings and higher efficiency levels to offer the Right Size solution to fit your configuration. This provides improved power delivery and the advantage of reclaiming lost power. Prior to making a power supply selection it is "highly recommended" that the "HP Power Advisor" is run to determine the right size power supply for your server configuration. The HP Power Advisor is located at "www.hp.com/go/proliant-energy-efficient" or www.hp.com/go/hppoweradvisor | 516914-B21 |
| HP 460W CS HE Power Supply Kit | 503296-B21 | |
| HP 750W CS HE Power Supply Kit | 512327-B21 | |
| HP 1200W CS HE Power Supply Kit | 500172-B21 | |
| HP 1200W-48V DC Common Slot Power Supply | 437573-B21 | |
| NOTE:
DC power supplies contain a -48V DC power cord designed for in rack
DC power rectifiers. NOTE: Option Kits contain optional power supply, an IEC power cable and PDU IEC cables. |
||
|
|
||
| Step 3: Choose Additional Factory Integratable Options (only one of the following from each list unless otherwise noted) | ||
| Controllers | NOTE: If Additional Memory Cache Module or Controller is Required please pick one of the following: | |
| HP 256 MB P-series
cache module FIO NOTE: Available for P410i only. |
534108-B21 | |
| 512MB BBWC | 462967-B21 | |
| HP Smart Array P212/256 MB w/ Battery FIO | 491191-B21 | |
| HP Smart Array P410/256 MB w/ Battery FIO | 491195-B21 | |
| HP Smart Array P411/256 MB w/ Battery FIO | 491193-B21 | |
| Integrated hypervisor (iHV) | NOTE: HP VMware ESXi free download from www.software.hp.com - select Virtualization | |
| HP VMware 3i Enterprise
2p Lic SW NOTE: For additional information and options kits, please see the QuickSpecs at: www.hp.com/go/vmware. |
430341-B21
|
|
| NOTE:
HP XenServer Select Edition free Download from: http://h20392.www2.hp.com/portal/swdepot/displayProductInfo.do? productNumber=HPXS |
||
| HP Essentials -XenServer Platinum Nm Lic |
530753-B21
|
|
| HP ProLiant Virtual Console Full License |
508293-B21
|
|
| XenServer HP Ent Upg iSW Lic |
464676-B21
|
|
| HP Citrix Essentials
for XenServer Enterprise Edition NOTE: For additional information and options kits, please see the HP Citrix Essentials for XenServer QuickSpecs at www.hp.com/go/citrix |
508294-B21
|
|
| Performance Packs | The HP ProLiant DL380
performance packs are necessary to configure a HP ProLiant DL380 Performance
Model. HP ProLiant DL380 Performance model includes the latest performance
technologies and enterprise class availability features pre-installed for
convenience and value. The performance pack includes a 2nd processor and
a redundant power supply. NOTE: Must also select Slimline SATA DVD RW Optical Drive (481043-B21) to achieve parity to DL380 High Performance Models. |
|
| HP DL380G6 2.6 HPM FIO Perf Pack |
500583-B21
|
|
| HP DL380G6 2.8 HPM FIO Perf Pack |
500584-B21
|
|
|
|
||
| Step 4: Choose Additional Options for Factory Integration |
| NOTE: For additional options, please refer to the "Core Options and Additional Options" section below. |
|
Содержание технического описания HP ProLiant DL380 Generation 6 |
Core Options
| NOTE: Some options may not be integrated at the factory. Contact your local sales representative for additional information. | ||
| | ||
| DL380 G6 Unique Options | HP StorageWorks
RDX160 Removable Disk Backup System DL Server Module NOTE: Mounts in DL380 G6 second drive cage slot (160GB of Disk Storage) | AP724A |
| HP StorageWorks RDX320 Removable
Disk Backup System DL Server Module NOTE: Mounts in DL380 G6 second drive cage slot (320GB of Disk Storage) | AP725A | |
| HP StorageWorks RDX500 Removable
Disk Backup System DL Server Module NOTE: Mounts in DL380 G6 second drive cage slot (500GB of Disk Storage) | AP726A | |
| HP
8SFF CAGE 380G6 NOTE: Second drive cage installation replaces internal optical bay. NOTE: Second drive cage requires second controller or HP SAS Expander Card (468406-B21). | 516914-B21 | |
| HP DL380G6 3 Slot PCI-E Riser Kit | 500579-B21 | |
| | ||
| Processors | Quad-Core Processors | |
| Intel® Xeon® Processor
E5504 (2.00 GHz, 4MB L3 Cache, 80W, DDR3-800) | 492136-B21 | |
| Intel® Xeon® Processor
E5506 (2.13 GHz, 4MB L3 Cache, 80W, DDR3-800) | 492131-B21 | |
| Intel® Xeon® Processor
L5506 (2.13 GHz, 4MB L3 Cache, 60W, DDR3-800) | 500089-B21 | |
| Intel® Xeon® Processor
E5520 (2.26 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) | 492239-B21 | |
| Intel® Xeon® Processor
L5520 (2.26 GHz, 8MB L3 Cache, 60W, DDR3-1066, HT, Turbo 1/1/2/2) | 500087-B21 | |
| Intel® Xeon® Processor
E5530 (2.40 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) | 492237-B21 | |
| Intel® Xeon® Processor
E5540 (2.53 GHz, 8MB L3 Cache, 80W, DDR3-1066, HT, Turbo 1/1/2/2) | 492244-B21 | |
| Intel® Xeon® Processor
X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) | 492234-B21 | |
| Intel® Xeon® Processor
X5560 (2.80 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) | 492232-B21 | |
| Intel® Xeon® Processor X5570 (2.93 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) | 500094-B21 | |
| Dual-Core Processors | ||
| Intel® Xeon® Processor E5502 (1.86 GHz, 4MB L3 Cache, 80W, DDR3-800) | 500085-B21 | |
| | ||
|
Memory |
Registered DIMMs (RDIMMs) | |
| HP 2GB 2Rx8 PC3-10600R-9 Kit |
500656-B21
|
|
| HP 4GB 2Rx4 PC3-10600R-9 Kit |
500658-B21
|
|
| HP 4GB 4Rx8 PC3-8500R-7 LP Kit |
500660-B21
|
|
| HP 8GB 2Rx4 PC3-8500R-7 Kit |
516423-B21
|
|
| HP 8GB 2Rx4 PC3-10600R-9 Kit | 500662-B21 | |
| Unbuffered with ECC DIMMs (UDIMMs) | ||
| HP 1GB 1Rx8 PC3-10600E-9 Kit | 500668-B21 | |
| HP 2GB 2Rx8 PC3-10600E-9 Kit | 500670-B21 | |
| NOTE: All DDR3
memory option kits consist of one DIMM per kit. For detailed memory configuration
rules and guidelines, please use the Online DDR3 Memory Configuration Tool:
www.hp.com/go/ddr3memory-configurator. NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient |
||
|
|
||
|
Optical Drives |
HP Slim SATA DVD RW Optical Drive NOTE: Included in performance models. |
481043-B21 |
| HP Slim SATA DVD-ROM Optical Drive | 481041-B21 | |
| | ||
| Hard Drives | NOTE: Transfer rates of drives are dependent on the maximum transfer rate supported by the HBA or Controller. Refer to the HBA or Controller technical specifications for details. | |
| SAS Hot Plug SFF Enterprise (ENT) Drives | ||
| HP 300GB 6G SAS 10K SFF DP ENT HDD |
507127-B21 | |
| HP
300GB 3G SAS 10K SFF DP ENT HDD |
492620-B21 | |
| HP 146GB 6G SAS 10K SFF DP ENT HDD |
507125-B21 | |
| HP 146GB 3G SAS 10K SFF DP ENT HDD |
418367-B21 | |
| HP 146GB 3G SAS 15K SFF DP ENT HDD |
504062-B21 | |
| HP 72GB 3G SAS 15K SFF DP ENT HDD |
418371-B21 | |
| HP 72GB 3G SAS 10K SFF DP ENT HDD |
384842-B21 | |
| HP 36GB 3G SAS 15K SFF DP ENT HDD |
418369-B21 | |
| NOTE:
SAS Enterprise drives have a 3-year warranty. Please see the QuickSpecs for Technical
Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12244_div/12244_div.html (Worldwide) | ||
| SATA Hot Plug Entry (ETY) Drives | ||
| HP 250GB 3G SATA 5.4K SFF ETY HDD | 460355-B21 | |
| HP 120GB 1.5G SATA 5.4K SFF ETY HDD | 458924-B21 | |
| NOTE: SATA drives
have a 1 year warranty. Please see the QuickSpecs for Technical Specifications
and additional information: http://h18000.www1.hp.com/products/quickspecs/13021_div/13021_div.html (Worldwide) | ||
| SAS Hot Plug 3.5" Enterprise (ENT) Drives | ||
| HP 450GB 3G SAS 15K 3.5" DP ENT HDD | 454232-B21 | |
| HP
400GB 3G SAS 10K 3.5" DP ENT HDD | 459508-B21 | |
| HP
300GB 3G SAS 15K 3.5" DP ENT HDD | 416127-B21 | |
| HP
146GB 3G SAS 15K 3.5" DP ENT HDD | 384854-B21 | |
| HP
72GB 3G SAS 15K 3.5" DP ENT HDD | 384852-B21 | |
| SAS
Hot Plug 3.5" Midline (MDL) Drives | ||
| HP
1TB 3G SAS 7.2K 3.5" DP MDL HDD | 461137-B21 | |
| HP 750GB 3G SAS 7.2K 3.5" DP MDL HDD | 461135-B21 | |
| SATA
Hot PlugMidline (MDL) Drives | ||
| HP 1TB 3G SATA 7.2K 3.5" MDL HDD | 454146-B21 | |
| HP
750GB 3G SATA 7.2K 3.5" MDL HDD | 458930-B21 | |
| HP
500GB 3G SATA 7.2K 3.5" MDL HDD | 458928-B21 | |
| HP
250GB 3G SATA 7.2K 3.5" MDL HDD | 458926-B21 | |
| HP 160GB 3G SATA 7.2K 3.5" MDL HDD | 458945-B21 | |
| | ||
| Communications | HP NC112T PCIe Gigabit Server Adapter |
503746-B21
|
| HP NC360T PCI Express Dual Port Gigabit Server Adapter |
412648-B21
|
|
| HP NC364T PCI Express Quad Port
Gigabit Server Adapter NOTE: Does not support Windows 2000. |
435508-B21
|
|
| HP NC373F PCI Express Multifunction Gigabit Server Adapter |
394793-B21
|
|
| HP NC373T PCI Express Multifunction Gigabit Server Adapter |
394791-B21
|
|
| HP NC382T PCI Express Dual Port Multifunction Gigabit Server Adapter |
458492-B21
|
|
| HP NC522SFP Dual Port 10GbE Server
Adapter NOTE: A minimum of two gigabyte (2 GB) of server memory is required per each NC522SFP adapter. |
468332-B21
|
|
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: www.hp.com/go/ProLiantNICs |
|
|
Riser Cage Options |
HP DL380G6 3 Slot PCI-E Riser Kit |
500579-B21
|
| HP DL385G5p PCI-X RIser Kit | 494322-B21 | |
| HP PCI x16 Riser Kit | 494323-B21 | |
|
|
||
| Redundant Options | CAUTION: In ProLiant Servers that have more than one power slot (bay), only same size power supplies are recommended. If non-matched power supplies are inserted you will get errors and operation will fail. | |
| HP 460W CS HE Power Supply Kit |
503296-B21
|
|
| HP 750W CS HE Power Supply Kit |
512327-B21
|
|
| HP 1200W CS HE Power Supply Kit |
500172-B21
|
|
| HP 1200W-48V DC Common Slot Power
Supply NOTE: DC power supplies contain a -48V DC power cord designed for in rack DC power rectifiers. |
437573-B21 | |
| NOTE: Option Kits contain optional power supply, an IEC power cable and PDU IEC cables. |
|
Содержание технического описания HP ProLiant DL380 Generation 6 |
Additional Options
| HP Insight Control Suite | NOTE: Electronic licensing options are available for Insight Control suites software products. Please see the appropriate Insight Control QuickSpecs for additional information. www.hp.com/go/ice | |
| HP Insight Control Suite | ||
| HP Insight Control suite, No Media 1-Server
License including 1 year of 24x7 Technical Support and Updates NOTE: This part number can be purchased as a single license or as multiple licenses with a single activation key. Customer will receive a license entitlement certificate via e-mail. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. | 452148-B22 | |
| HP Insight Software Media Kit NOTE: Insight Software DVD media without licenses. Contains Insight Manager and Insight Software products and components licensed by Insight Control suite. Uses an integrated installer to perform quick and accurate software installation and updates. | 436222-B21 | |
| NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12631_div/12631_div.html | ||
| HP Insight Control Linux Edition | ||
| HP Insight Control Environment for Linux,
Media pack (DVD) - No licenses included NOTE: This optional Media pack DVD contains the ISO image for HP Insight Control Environment for Linux, HP System Insight Manager, HP Insight Power Manager, HP Insight Virtual Machine Manager software for ProLiant, and an integrated installer. Servers must be acquired separately. NOTE: This Media pack is optional because the latest ISO image and latest updates may be downloaded at no cost from: http://www.hp.com/go/ice-linux (click on Download button). |
464422-B22 | |
| HP
Insight Control Environment for Linux, No Media, 1-Server license, including one
year of 24x7 Technical Support and Updates NOTE: This part number can be used to purchase one (1) license with a single activation key. Customer will receive a printed license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. NOTE: One certificate is shipped for each license. |
464423-B22 | |
| NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/13019_div/13019_div.html | ||
| | ||
| Server Management Stand Alone Software | NOTE: Electronic licensing options are available for select software products. Please see the appropriate Insight Software standalone product QuickSpecs for additional information. | |
| Deploy | ||
| HP Insight Rapid Deployment software | ||
| HP Insight Rapid Deployment software No Media
1-Server License including 1 year of 24x7 Technical Support and Updates NOTE: This license allows 1 server to be deployed and managed via RDP. Customer will receive a printed license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support Service NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11053_div/11053_div.html |
452151-B21 | |
| HP Insight Server Migration software for ProLiant | ||
| HP Insight Server Migration software for
ProLiant, No Media, Physical / Virtual to ProLiant Single Migration License,
including 1 year of 24x7 Technical Support and Updates NOTE: This license allows 1 physical to ProLiant or virtual to ProLiant migration. Customer will receive a printed license entitlement certificate and documentation via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. |
460750-B21 | |
| HP Insight Server Migration software for
ProLiant, No Media, Physical / Virtual to Virtual Single Migration License,
including 1 year of 24x7 Technical Support and Updates NOTE: This license allows 1 physical to virtual or virtual to virtual migration. Customer will receive a printed license entitlement certificate and documentation via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. |
460753-B21 | |
| HP Insight Server Migration software for
ProLiant, No Media, 1-Year Unlimited Migration License, including 1 year
of 24x7 Technical Support NOTE: This license allows unlimited migrations (physical to ProLiant, physical to virtual, virtual to virtual, and virtual to ProLiant) for one year. Customer will receive a printed license entitlement certificate and documentation via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support Service. |
460756-B21 | |
| NOTE:
For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12855_div/12855_div.html |
||
| Monitor | ||
| HP Insight Dynamics-VSE suite for ProLiant | ||
| HP Insight Dynamics-VSE
with Insight Control Environment, 1-server license including 1 year of 24x7
Technical Support and Updates NOTE: This license supports HP ProLiant ML/DL servers and c-Class Blade servers. Customer will receive a printed license entitlement certificate via physical shipment. |
483527-B21 | |
| HP Insight Dynamics-VSE
without Insight Control Environment, 1-server license including 1 year of
24x7 Technical Support and Updates NOTE: This license supports HP ProLiant ML/DL and c-Class Blade servers. Customer will receive via email a receipt and link to a license entitlement certificate. |
483531-B21 | |
| NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/13050_div/13050_div.html | ||
| Control | ||
| Integrated Lights-Out Advanced Pack | ||
| HP Integrated Lights-Out Advanced Pack, No
Media, 1-Server License, including 1 year of 24x7 Technical Support and
Updates NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12362_div/12362_div.html |
512485-B21 | |
| HP Insight Control Environment iLO Advanced
Upgrade, No Media, 1-Server License including one year of 24x7 support NOTE: For use in environments where iLO Advanced Pack is already installed and licensed. Customer will receive a printed license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12631_div/12631_div.html |
506503-B21 | |
| Optimize | ||
| HP Insight Power Manager software (IPM) | ||
| HP Insight Power Manager software, No Media,
1-Server License, including 1 year of 24x7 Technical Support and Updates NOTE: Customers purchasing this upgrade must already have an iLO Advanced or Select license on each managed server. Customer will receive a printed license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12623_div/12623_div.html |
452677-B21 | |
| HP Insight Virtual Machine Manager software for ProLiant | ||
| HP Insight Virtual Machine Manager software
for ProLiant, No Media, 1-Server License, including 1 year of 24x7 Technical
Support and Updates NOTE: Customer will receive a printed license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12328_div/12328_div.html |
452153-B21 | |
| NOTE: Flexible and volume quantity license kits are available for Value Packs. Refer to: http://www.hp.com/servers/proliantessentials or the various QuickSpecs for more information. | ||
|
|
||
|
Drive Cage Options |
HP 8SFF CAGE 380G6 NOTE: Second drive cage installation replaces internal optical bay. NOTE: Second drive cage requires second controller or HP SAS Expander Card (468406-B21). |
516914-B21
|
|
|
||
|
Secure Digital (SD) Memory Cards |
HP Photosmart 2GB Secure Digital (SD) Card |
L1877A
|
| HP Photosmart 4GB Secure Digital High Speed Card (SDHC) | L1878A#707 | |
|
|
||
|
Security |
HP Trusted Platform Module Option Kit |
488069-B21
|
|
|
||
| Storage Controllers | SAS Controllers | |
| Smart Array P800 Controller | ||
| HP Smart Array P800/512 BBWC Controller |
381513-B21
|
|
| Smart Array P212 Controller | ||
| HP Smart Array P212/Zero Memory Controller |
462828-B21
|
|
| HP Smart Array P212/256 MB Controller | 462834-B21 | |
| 256 MB Cache | 462968-B21 | |
| Smart Array P410 Controller | ||
| HP Smart Array P410/256 MB Controller |
462862-B21
|
|
| Battery Kit (for Battery Backed
Write Cache) NOTE: When used with the embedded HP Smart Array P410i controller, this battery module also requires a 24 inch SFP Battery Cable (496029-B21). |
462969-B21 | |
| HP Smart Array P410/512 MB with BBWC Controller |
462864-B21
|
|
| 512MB BBWC |
462967-B21
|
|
| Smart Array P411 Controller | ||
| HP Smart Array P411/256 MB Controller |
462830-B21
|
|
| HP Smart Array P411/512 MB with BBWC Controller |
462832-B21
|
|
| 512MB BBWC | 462967-B21 | |
| NOTE: Please see
the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12616_div/12616_div.html (Smart Array P800 Controller) http://h18000.www1.hp.com/products/quickspecs/13203_div/13203_div.html (Smart Array P212 Controller) http://h18000.www1.hp.com/products/quickspecs/13201_div/13201_div.html (Smart Array P410 Controller) http://h18000.www1.hp.com/products/quickspecs/13202_div/13202_div.html (Smart Array P411 Controller) |
||
| HP Smart Array Advanced Pack | ||
| HP Smart Array Advanced Pack No
Media 1-Server license including 1yr 24x7 Technical Support NOTE: This part number can be used to purchase a single license or to order multiple licenses with a single activation key. Customers will receive a license entitlement certificate via e-mail. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Include one year of 24x7 HP Software Technical Support Services. |
516471-B21 | |
| NOTE: Please see
the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/13200_div/13200_div.html |
||
| SAS Controller Options | ||
| HP SAS Expander Card | 468406-B21 | |
| NOTE:
Please see the QuickSpecs for Technical Specifications and additional information: http://h18004.www1.hp.com/products/quickspecs/13232_div/13232_div.html (SAS Expander Card) |
||
| SAS HBA | ||
| HP SC08Ge Host Bus Adapter NOTE: For use with additional 8 SFF drive cage (516914-B21). |
488765-B21 | |
| NOTE: Please see
the QuickSpecs for Technical Specifications and additional information: http://h18004.www1.hp.com/products/quickspecs/13082_div/13082_div.html (SC08Ge HBA) |
||
| SCSI HBA | ||
| HP SC11Xe Host Bus Adapter |
412911-B21
|
|
|
NOTE: Please see the QuickSpecs for
additional information: |
||
|
|
||
| Power Cords | NOTE: HP ProLiant servers ships with an IEC-IEC power cord used for rack mounting with Power Distribution Units (PDUs). | |
| Nema 5-15P to IEC320-C13, North America low voltage (6 ft/2 m) | AF556A | |
| Power Cord, Euro, 10A 250 V Straight (6 ft/1.83 m) |
AF568A
|
|
| Power Cord, UK, 10A 250 V Straight (6 ft/1.83 m) |
AF570A
|
|
| Power Cord, Danish, 10A 250 V Straight (6 ft/1.83 m) |
AF566A
|
|
| Power Cord, Swiss, 10A 250 V Straight (6 ft/1.83 m) |
AF565A
|
|
| Power Cord, Italian, 10A 250 V Straight (6 ft/1.83 m) |
AF571A
|
|
| Power Cord, South Africa, 10A 250 V Straight (8.2 ft/2.5 m) |
AF567A
|
|
| HPC Specific Options | HP IB 4X QDR PCI-e G2 Dual Port HCA |
517721-B21 |
| NOTE: Please see the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/13078_div/13078_div.html |
|
| Tape Drives |
NOTE: For the complete listing of Tape Drive offerings, please
see: |
|
| USB Rack-Mount Tape Solutions | ||
| HP StorageWorks 1U USB Rack-Mount
Kit with one DAT 160 USB Tape Drive NOTE: Pre-configured with one DAT 160 USB tape drive. |
AG703A
|
|
| SAS Rack-Mount
Tape Solutions NOTE: HP recommends purchasing the HP Smart Array P212 Controller (462828-B21) for a dedicated SAS HBA for tape. |
||
| HP StorageWorks 1U SAS Rack-Mount
Kit with one LTO-4 Ultrium 1760 NOTE: Pre-configured with one LTO-4 Ultrium 1760 SAS tape drive. |
EH946A
|
|
| HP StorageWorks 1U SAS Rack-Mount
Kit NOTE: Supports up to (2) half-height SAS tape drives. |
AE459A
|
|
| HP StorageWorks LTO-2 Ultrium
448 SAS Internal Tape Drive NOTE: Mounts inside the 1U SAS Rack-Mount Kit (AE459A). |
DW085A
|
|
| HP StorageWorks LTO-3 Ultrium
920 SAS Internal Tape Drive NOTE: Mounts inside the 1U SAS Rack-Mount Kit (AE459A). |
EH847A
|
|
| SCSI Rack-Mount Tape Solutions NOTE: SCSI Controller required. HP recommends purchasing the HP SC11Xe HBA (412911-B21) for a dedicated SCSI HBA for tape. |
||
| HP StorageWorks 1U SCSI Rack-mount
kit with one LTO-2 Ultrium 448 SCSI Tape Drive (Carbonite) NOTE: Pre-configured with one LTO-2 Ultrium 448 SCSI tape drive. |
DW028B
|
|
| HP StorageWorks 1U SCSI Rack-mount
kit with one LTO-3 Ultrium 920 NOTE: Pre-configured with one LTO-3 Ultrium 920 SCSI tape drive. |
EH903A
|
|
| HP StorageWorks 3U SCSI Rack-Mount
with 1 LTO-4 Ultrium 1840 Tape Drive NOTE: Pre-configured with one LTO-4 Ultrium 1840 SCSI tape drive. |
EH926A
|
|
|
NOTE: Please see the Rack-Mount Tape
Drive Kits QuickSpecs for additional information regarding these kits: |
||
| NOTE: Please see
the QuickSpecs for additional options and configuration information at:
http://h18000.www1.hp.com/products/quickspecs/10854_div/10854_div.html (Worldwide) |
||
|
|
||
| Disk-Based Backup | RDX Removable Disk Backup | |
| HP
StorageWorks RDX160 Removable Disk Backup System DL Server Module NOTE: Mounts in DL380 G6 media bay (160GB of Disk Storage) |
AP724A | |
| HP
StorageWorks RDX320 Removable Disk Backup System DL Server Module NOTE: Mounts in DL380 G6 media bay (320GB of Disk Storage) | AP725A | |
| HP StorageWorks RDX500 Removable Disk
Backup System DL Server Module NOTE: Mounts in DL380 G6 media bay (500GB of Disk Storage) | AP726A | |
| NOTE: Please
see the HP RDX Removable Disk Backup System QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/13036_div/13036_div.html | ||
| D2D Backup | ||
| HP StorageWorks D2D120 Backup
System with Data Protector Express Software Kit NOTE: 2TB of Disk Storage. |
EH924A | |
| HP
StorageWorks D2D130 Backup System with LTO-3 Ultrium 920 SAS Tape Drive NOTE: 3TB of Disk Storage. |
EH952A | |
| HP
StorageWorks D2D2503i Backup System NOTE: 3TB of Disk Storage. | EH945A | |
| HP StorageWorks D2D4004i Backup
System NOTE: 4.5TB of Disk Storage. | EH938A | |
| NOTE: Please see the HP D2D Backup Systems QuickSpecs for additional information: http://www.hp.com/go/d2d | ||
| | ||
| Tape Autoloaders | HP StorageWorks DAT Autoloader | |
| HP StorageWorks DAT 72x10 tape autoloader | AE313B | |
| HP StorageWorks 1/8 G2 Tape Autoloader | ||
| HP StorageWorks 1/8 G2 LTO-4 Ultrium 1760 SAS Tape Autoloader | AK377A | |
| HP StorageWorks 1/8 G2 LTO-3 Ultrium 920 SAS Autoloader | AH558A | |
| HP StorageWorks 1/8 G2 LTO-2 Ultrium 448 Tape Autoloader | AH164A | |
| HP StorageWorks 1/8 G2 Tape Autoloader
Rack Kit NOTE: Required to install the 1/8 G2 Autoloaders in a standard 19-inch rack; includes rails and rackmount instructions. |
AH166A | |
| NOTE: Please reference the Tape Autoloader QuickSpecs at: http://www.hp.com/go/automation for additional information needed to create a complete solution. | ||
|
|
||
|
Tape Libraries |
HP StorageWorks MSL2024 Tape Library | |
| HP StorageWorks MSL2024 1 LTO-4 Ultrium 1840 SCSI Drive Library | AJ033A | |
| HP StorageWorks MSL2024 1 LTO-4 Ultrium 1760 SAS Drive Library | AK378A | |
| HP StorageWorks MSL2024 1 LTO-3 Ultrium 960 SCSI Drive Library | AG115A | |
| HP StorageWorks MSL2024 1 LTO-3 Ultrium 920 SAS Drive Library | AH559A | |
| HP StorageWorks MSL2024 1 LTO-2 Ultrium 448 SCSI Drive Library | AG116A | |
| HP StorageWorks MSL4048 Tape Library | ||
| HP StorageWorks MSL4048 1 LTO-4 Ultrium 1840 SCSI Drive Library | AJ035A | |
| HP StorageWorks MSL4048 2 LTO-4 Ultrium 1760 SAS Drive Library | AK380A | |
| HP StorageWorks MSL4048 1 LTO-3 Ultrium 960 SCSI Drive Library | AG322A | |
| HP StorageWorks MSL4048 1 LTO-3 Ultrium 920 SAS Drive Library | AH560A | |
| NOTE: Please reference the MSL Tape Library QuickSpecs at: http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at: http://www.hp.com/go/ebs. | ||
|
|
||
| High Availability Cluster Options | HP Serviceguard for Linux | |
| HP Serviceguard for Linux on HP
ProLiant and other third-party x86 Servers - Physical Media Kit NOTE: This kit contains media only. |
519353-B21
|
|
| HP Serviceguard for Linux on HP
ProLiant and other third-party x86 Servers Single-Server License Licensed per Server NOTE: This license allows Serviceguard for Linux to be installed on 1 server. Customer will receive a printed license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. |
519354-B21
|
|
| HP Serviceguard for Linux - Flexible-Quantity
License (for HP ProLiant and other third-party x86 servers) Licensed per Server NOTE: This part number can be used to purchase multiple licenses with a single activation key. Customer will receive a printed license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. |
519355-B21
|
|
| HP Serviceguard Linux Oracle Database
Toolkit for HP ProLiant/x86 Servers Licensed per cluster Includes media and One Year 24x7 Software Support & Updates |
463833-B21
|
|
| HP Serviceguard Extension for
SAP on Linux for HP ProLiant/x86 Servers Licensed per physical server Includes media and One Year 24x7 Software Support & Updates |
463834-B21 | |
| HP Serviceguard Linux Extended
Distance Cluster (XDC) for HP ProLiant/x86 Servers Licensed per physical server Includes media and One Year 24x7 Software Support & Updates |
463835-B21 | |
| NOTE: The above
is not a complete list of all HP Serviceguard for Linux product numbers
For a detailed list of supported configuration/certification options for
HP Serviceguard for Linux please refer to the HP Serviceguard for Linux
Configuration & Ordering Guide available at: http://www.hp.com/go/sglx/info. NOTE: HP Serviceguard for Linux products running on x86 platforms now include one year of 24 x 7 Software Technical Support and Updates. Please see the Support Information section of the HP Serviceguard for Linux QuickSpecs for details. NOTE: For additional information including a complete list of Product Numbers for HP Serviceguard for Linux, please see the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11518_div/11518_div.html (Worldwide) |
||
|
|
||
| StorageWorks Options | StorageWorks Fibre Channel HBA | |
| NOTE: For the complete listing of Fibre Channel Host Bus Adapters for Windows 2000, Windows Server 2003 and Linux, please see: http://h18006.www1.hp.com/storage/saninfrastructure/hba.html | ||
| HP StorageWorks FC2142SR 4Gb PCI-e HBA | A8002A | |
| HP StorageWorks FC2242SR Dual Channel 4Gb PCI-e HBA |
A8003A | |
| HP StorageWorks FC1142SR 4Gb PCI-e HBA |
AE311A | |
| HP StorageWorks FC1242SR Dual Channel 4Gb PCI-e HBA |
AE312A | |
| HP StorageWorks 81Q 8Gb PCI-e FC HBA |
AK344A | |
| HP StorageWorks 81E 8Gb PCI-e FC HBA | AJ762A | |
| HP StorageWorks 82E 8Gb Dual-port
PCI-e FC HBA | AJ763A | |
| HP StorageWorks 82Q 8Gb Dual
Port PCI-e FC HBA | AJ764A | |
| HP
StorageWorks FC2143 4Gb PCI-X 2.0 FC HBA | AD167A | |
| HP
StorageWorks FC2243 Dual Channel 4Gb PCI-X 2.0 FC HBA | AD168A | |
| HP
StorageWorks FC1143 4Gb PCI-X 2.0 FC HBA | AB429A | |
| HP StorageWorks FC1243 Dual Channel 4Gb PCI-X 2.0 FC HBA | AE369A | |
| StorageWorks SCSI HBA | ||
| HP
U320e SCSI Host Bus Adapter NOTE: Recommended Dual Channel Ultra320 SCSI Controller for connecting multi-drive MSL tape libraries to ProLiant servers. |
AH627A | |
| | ||
|
HP StorageWorks 50 Modular Smart Array |
HP StorageWorks 50 Modular Smart Array |
364430-B21
|
| NOTE: Please see the QuickSpecs for additional options and configuration information at: http://h18000.www1.hp.com/products/quickspecs/12245_div/12245_div.html (Worldwide) | ||
| | ||
|
HP StorageWorks 60 Modular Smart Array |
HP StorageWorks 60 Modular Smart Array |
418408-B21
|
| NOTE: Please see the QuickSpecs for additional options and configuration information at: http://h18000.www1.hp.com/products/quickspecs/12627_div/12627_div.html (Worldwide) | ||
| | ||
|
HP StorageWorks 70 Modular Smart Array |
HP StorageWorks 70 Modular Smart Array |
418800-B21
|
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12652_div/12652_div.html (Worldwide) | ||
| | ||
|
HP StorageWorks 2000sa Modular Smart Array |
HP 2012sa Single Controller Modular Smart Array |
AJ752A
|
| HP 2012sa Dual Controller Modular Smart Array | AJ753A | |
| NOTE: Please see the QuickSpecs for additional options and configuration information at: http://h18000.www1.hp.com/products/quickspecs/13045_div/13045_div.html (Worldwide) | ||
|
|
||
|
Uninterruptible Power Systems - Rack |
HP R1500 G2 UPS | |
| HP, R1.5kVA UPS, 1U, NA |
AF419A
|
|
| HP, R1.5kVA UPS, 1U, INTL |
AF418A
|
|
| HP, R1.5kVA UPS, 1U, JPN/TW |
AF421A
|
|
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12507_div/12507_div.html (Worldwide) | ||
| HP R3000v Uninterruptible Power System | ||
| HP R3000v UPS NOTE: The R3000v is available in China and India only. |
AF444A
|
|
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13129_div/13129_div.html (Worldwide) | ||
| NOTE: For additional information on HP Uninterruptable Power Systems please go to: www.hp.com/servers/rackups. | ||
|
|
||
|
HP Monitored Power Distribution Unit (PDU) |
HP Monitored Power Distribution Unit: Full Rack Version | |
| HP 17.3 kVA S2324 Monitored PDU- dual input, 3Ø24A (NA/JPN) |
AF503A
| |
| HP 8.6 kVA S1324 Monitored PDU- single input, 3Ø, 24A (NA/JPN) |
AF504A
| |
| HP 16.6 kVA S2140 Monitored PDU- dual input, 1Ø, 40A (NA/JPN) |
AF505A
| |
| HP 8.3 S1140 Monitored PDU- single input, 1Ø, 40A (NA/JPN) |
AF506A
| |
| HP 22.1 kVA S2316 Monitored PDU- dual input, 3Ø, 16A (INTL) |
AF507A
| |
| HP 11 kVA S1316 Monitored PDU- single input, 3Ø, 16A (INTL) |
AF508A
| |
| HP 14.7 kVA S2132 Monitored PDU- dual input, 1Ø, 32A (INTL) |
AF509A
| |
| HP 7.3 kVA S1132 Monitored PDU- single input, 1Ø, 32A (INTL) |
AF510A
| |
| HP Monitored Power Distribution Unit: Half Rack Version | ||
| HP 4.9 kVA S124 Monitored PDU- single input, 1Ø, 24A (NA/JPN) |
AF914A
| |
| HP 7.3 kVA S132 Monitored PDU- single input, 1Ø, 32A (INTL) |
AF915A
| |
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12118_div/12118_div.html (Worldwide) | ||
|
| ||
| USB Options | HP USB 2-Button Optical Scroll Mouse (Carbonite/Silver) |
DC172B
|
| 1.44MB External USB Floppy Drive |
DC141B
|
|
| HP USB 04 Standard Keyboard |
DT528A#ABA
|
|
|
|
||
| HP Rack 5000 Series (Graphite Metallic) | HP 5642 Rack-Unassembled |
358254-B21
|
|
NOTE: Please see the QuickSpecs for Technical Specifications and
additional information: http://h18000.www1.hp.com/products/quickspecs/12074_div/12074_div.html
(Worldwide) |
||
| | ||
|
HP Rack 10000 G2 Series | 10642 G2 (42U) Rack Cabinet - Pallet |
AF001A |
| 10642 G2 (42U) Rack Cabinet - Shock Pallet |
AF002A | |
| 10642 G2 (42U) Rack Cabinet - Crated |
AF003A | |
| 10642 G2 (42U) Rack Cabinet, with Extension - Shock Pallet | AF004A | |
| 10636 G2 (36U) Rack Cabinet - Pallet | AF011A | |
| 10636 G2 (36U) Rack Cabinet - Shock Pallet | AF012A | |
| 10636 G2 (36U) Rack Cabinet - Crated | AF013A | |
| 10636 G2 (36U) Rack Cabinet, with Extension - Shock Pallet |
AF014A | |
| 10622 G2 (22U) Rack Cabinet - Pallet |
AF021A | |
| 10622 G2 (22U) Rack Cabinet - Shock Pallet |
AF022A | |
| 10642 G2 (42U) Rack Cabinet 1200mm Deep - Shock Pallet | AF034A | |
| 10642 G2 (42U) Rack Cabinet 1200mm Deep - Pallet | AF038A | |
| 10842 G2 (42U) 800mm Wide Rack Cabinet - Pallet |
AF041A | |
| 10842 G2 (42U) 800mm Wide Rack Cabinet - Shock Pallet |
AF042A | |
| 10647 G2 (47U) Rack Cabinet - Pallet |
AF031A | |
| HP S10614 (14U) Rack Cabinet - Shock Pallet | 292302-B22 | |
| 10647 G2 (47U) Rack Cabinet 1200mm
Deep - Shock Pallet NOTE: Due to handling and shipping requirements, AF044A is only orderable through HP Factory Express. It is not for direct sales. Customer site surveys are required before an order is approved. CTO orders may require additional lead time. | AF044A | |
| 10647 G2 (47U) Rack Cabinet 1200mm Deep - Pallet | AF045A | |
| NOTE: It is mandatory
to use a shock pallet when shipping racks with equipment installed. NOTE: xxxxxx-B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels). | ||
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12402_div/12402_div.html (Worldwide) | ||
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. | ||
| | ||
| Keyboards and Monitors | TFT7600 Rackmount Keyboard Monitor US |
AG052A
|
| TFT7600 Rackmount Keyboard Monitor UK |
AG053A
|
|
| TFT7600 Rackmount Keyboard Monitor GR |
AG054A
|
|
| TFT7600 Rackmount Keyboard Monitor FR |
AG055A
|
|
| TFT7600 Rackmount Keyboard Monitor IT |
AG056A
|
|
| TFT7600 Rackmount Keyboard Monitor SP |
AG057A
|
|
| TFT7600 Rackmount Keyboard Monitor DEN |
AG058A
|
|
| TFT7600 Rackmount Keyboard Monitor NOR |
AG059A
|
|
| TFT7600 Rackmount Keyboard Monitor SE/FI |
AG060A
|
|
| TFT7600 Rackmount Keyboard Monitor SWI |
AG061A
|
|
| TFT7600 Rackmount Keyboard Monitor PORT |
AG062A
|
|
| TFT7600 Rackmount Keyboard Monitor BEL |
AG063A
|
|
| TFT7600 Rackmount Keyboard Monitor JPN2 |
AG064A
|
|
| TFT7600 Rackmount Keyboard Monitor RUS |
AG065A
|
|
| TFT7600 Rackmount Keyboard Monitor INTL |
AG066A
|
|
| 1U Rackmount Keyboard with USB, US |
AG072A
|
|
| 1U Rackmount Keyboard with USB, UK |
AG073A
|
|
| 1U Rackmount Keyboard with USB, GR |
AG074A
|
|
| 1U Rackmount Keyboard with USB, FR |
AG075A
|
|
| 1U Rackmount Keyboard with USB, ITL |
AG076A
|
|
| 1U Rackmount Keyboard with USB, SP |
AG077A
|
|
| 1U Rackmount Keyboard with USB, DEN |
AG078A
|
|
| 1U Rackmount Keyboard with USB, NOR |
AG079A
|
|
| 1U Rackmount Keyboard with USB, SE/FI |
AG080A
|
|
| 1U Rackmount Keyboard with USB, SWI |
AG081A
|
|
| 1U Rackmount Keyboard with USB, PORT |
AG082A
|
|
| 1U Rackmount Keyboard with USB, BEL |
AG083A
|
|
| 1U Rackmount Keyboard with USB, JPN2 |
AG084A
|
|
| 1U Rackmount Keyboard with USB, RUS |
AG085A
|
|
| 1U Rackmount Keyboard with USB, INTL |
AG086A
|
|
| NOTE: For additional information regarding Rack Options, please see the following URL: http://www.hp.com/go/rackandpower. | ||
|
|
||
| HP KVM Switch Options | 2x1x16 IP Console Switch with Virtual Media |
AF601A
|
| 4x1x16 IP Console Switch with Virtual Media |
AF602A
|
|
| 2x16 Server Console Switch with Virtual Media |
AF600A
|
|
| PS/2 Virtual Media Interface Adapter,
1 pack NOTE: Requires PS/2 and one USB port on server. |
AF604A
|
|
| Server console switch 0x2x8 |
AF616A
|
|
| Server console switch 0x2x16 |
AF617A
|
|
| PS/2 Interface Adapter, 1 pack |
262588-B21
|
|
| PS/2 Interface Adapter, 8 pack |
262587-B21
|
|
| NOTE: Cat5e cables are required to connect Interface Adapters to Console Switches. Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. | ||
| HP 1x4 Console Switch |
AF611A
|
|
| HP PS2 Server Console Cable, 6 foot, 2-Pack |
AF612A
|
|
| HP USB Server Console Cable, 6
foot, 2-Pack NOTE: Required for supporting USB peripherals. |
AF613A
|
|
| NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. | ||
|
|
||
| HP Serial Console Server Options | HP 16 Port Serial Console Server (worldwide) |
AF101A
|
| HP 48 Port Serial Console Server (worldwide) |
AF102A
|
|
| Serial Adapter, RJ45-DB9 DCE Female, 1 Pack |
AF103A
|
|
| Serial Adapter, RJ45-DB9 DCE Female, 8 Pack |
AF110A
|
|
| NOTE: Cat5e cables are required to connect Serial Adapters to Serial Console Servers. Additional Serial Adapters and Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. | ||
| NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. | ||
|
|
||
| Service
and Support Offerings (HP Care Pack Services) |
Hardware Services On-site Service | |
| 4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic |
U4544E
|
|
| 4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic |
U4545E
|
|
| Hardware Services 6-Hour Call to Repair On-site Service | ||
|
6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic |
U4546E
|
|
| Installation & Start-up Services | ||
| Hardware Installation, Electronic |
U4554E
|
|
| Installation & Start-Up of a ProLiant server and Microsoft or Linux O/S per the Customer Description and/or Data Sheet. To be delivered on a scheduled basis 8am-5pm, M-F, excl. HP holidays, Electronic |
U4555E
|
|
| Installation and Startup for Essentials Rapid Deployment Pack, Electronic |
U5683E
|
|
| Support Plus | ||
| Onsite HW support, 8am-9pm, M-F, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays, Electronic |
U4556E
|
|
| Support Plus 24 | ||
| Onsite HW support 24x7, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic |
U4557E
|
|
| Onsite HW support 24x7, 4hr response and SuSE Linux SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic |
U6312E
|
|
| Onsite HW support 24x7, 4hr response and Red Hat ES Linux SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic |
U8334E
|
|
| NOTE: For more information, customer/resellers can contact: http://www.hp.com/services/carepack |
|
Содержание технического описания HP ProLiant DL380 Generation 6 |
Memory
| NOTE: Memory configurations listed do not apply to "Factory Integrated Models". |
|
DDR3 memory population guidelines
|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
NOTES:
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
DIMM slot and configuration diagrams
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Standard memory configuration (1 CPU model)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Standard memory plus optional memory (1 CPU model)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Standard memory replaced
with optional memory (1 CPU model)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| UDIMM maximum configuration (1 CPU model)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Standard memory replaced
with optional memory (2 CPU model)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| UDIMM maximum configuration
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| NOTE: Capacity references are rounded to the common Gigabyte values.
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Following are memory options available from HP: | ||
| Memory | Registered DIMMs (RDIMMs) | |
| HP 2GB 2Rx8 PC3-10600R-9 Kit | 500656-B21 | |
| HP 4GB 2Rx4 PC3-10600R-9 Kit | 500658-B21 | |
| HP 4GB 4Rx8 PC3-8500R-7 LP Kit | 500660-B21 | |
| HP 8GB 2Rx4 PC3-8500R-7 Kit | 516423-B21 | |
| HP 8GB 2Rx4 PC3-10600R-9 Kit | 500662-B21 | |
| Unbuffered with ECC DIMMs (UDIMMs) | ||
| HP 1GB 1Rx8 PC3-10600E-9 Kit | 500668-B21 | |
| HP 2GB 2Rx8 PC3-10600E-9 Kit | 500670-B21 | |
| NOTE: All DDR3
memory option kits consist of one DIMM per kit. For detailed memory configuration
rules and guidelines, please use the Online DDR3 Memory Configuration Tool:
www.hp.com/go/ddr3memory-configurator. NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient |
||
|
Содержание технического описания HP ProLiant DL380 Generation 6 |
Storage
![]() |
1-8
|
Eight SFF SAS hot plug hard drive bays |
![]() |
1-16 | Sixteen SFF SAS hot plug hard
drive bays NOTE: This configuration does not support optical drive. |
![]() |
1-6 | Six LFF SAS hot plug hard drive
bays NOTE: This configuration does not support optical drive. |
| Drive Support | |||
|
| |||
|
Quantity |
Position |
Controller | |
|
Removable Media | |||
| HP Slim SATA DVD RW Optical Drive NOTE: Included in performance models. |
Only 1 available removable media bay |
Slimline bay | Integrated
SATA NOTE: Optional |
| HP Slim SATA DVD-ROM Optical Drive | Only
1 available removable media bay |
Slimline bay | Integrated
SATA NOTE: Optional |
| | |||
|
Hard Drives NOTE: Transfer rates of drives are dependent on the maximum transfer rate supported by the HBA or Controller. Refer to the HBA or Controller technical specifications for details. | |||
| SAS Hot Plug SFF Enterprise (ENT) Drives | |||
| Quantity Supported |
Position Supported | Controller | |
| 300GB 3G
SAS 10K DP 300GB 6G SAS 10K DP 146GB 6G SAS 10K DP 146GB 3G SAS 15K DP 146GB 3G SAS 10K DP 72GB 3G SAS 10K DP 72GB 3G SAS 15K DP 36GB 3G SAS 15K DP | Up
to 8 | 1-8 |
HP Smart Array P800/512 BBWC Controller HP Smart Array P212/Zero Memory Controller HP Smart Array P212/ 256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
| NOTE: Second SFF drive cage requires second controller or HP SAS Expander Card (PN 468406-B21). | |||
| SATA Hot Plug Entry (ETY) Drives | |||
|
Quantity Supported |
Position Supported | Controller | |
| 250GB 3G
SATA 5.4K 120GB 1.5G SATA 5.4K |
Up to 8 |
1-8 | HP
Smart Array P800/512 BBWC Controller HP Smart Array P212/Zero Memory Controller HP Smart Array P212/ 256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
| NOTE: Second SFF drive cage requires second controller or HP SAS Expander Card (PN 468406-B21). | |||
| SAS Hot Plug 3.5" Enterprise (ENT) Drives | |||
| Quantity Supported |
Position Supported | Controller | |
| 450GB 3G
SAS 15K DP 400GB 3G SAS 10K DP 300GB 3G SAS 15K DP 146GB 3G SAS 15K DP 72GB 3G SAS 15K DP |
Up to 6 |
1-6 |
HP Smart Array P800/512 BBWC Controller HP Smart Array P212/Zero Memory Controller HP Smart Array P212/ 256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
| SAS Hot Plug 3.5" Midline (MDL) Drives | |||
|
Quantity Supported |
Position Supported | Controller | |
| 1TB 3G SAS
7.2K DP 750GB 3G SAS 7.2K DP |
Up to 6 |
1-6 | HP
Smart Array P800/512 BBWC Controller HP Smart Array P212/Zero Memory Controller HP Smart Array P212/ 256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
| SATA Hot Plug Midline (MDL) Drives | |||
|
Quantity Supported |
Position Supported | Controller | |
| 1TB 3G SATA
7.2K 750GB 3G SATA 7.2K 500GB 3G SATA 7.2K 250GB 3G SATA 7.2K 160GB 3G SATA 7.2K | Up
to 6 | 1-6 | HP
Smart Array P800/512 BBWC Controller HP Smart Array P212/Zero Memory Controller HP Smart Array P212/ 256 MB Controller HP Smart Array P410/256 MB Controller HP Smart Array P410/512 MB BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
|
| |||
|
External Storage | |||
| Quantity |
Position |
Host Controller or Adapter | |
| 50 Modular Smart Array |
Up to 4 |
External | HP Smart Array P800/512 BBWC Controller |
| 60 Modular Smart Array |
Up to 4 |
External | HP
Smart Array P212/Zero Memory Controller HP Smart Array P212/ 256 MB Controller |
| Up
to 8 | External | HP
Smart Array P800/512 BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller | |
| 70 Modular Smart Array |
Up to 2 |
External | HP
Smart Array P212/Zero Memory Controller HP Smart Array P212/ 256 MB Controller |
| Up
to 4 | External | HP
Smart Array P800/512 BBWC Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller | |
| HP 2000sa Modular Smart Array Controller | Up to 4 | External | HP SC08Ge Host Bus Adapter |
|
| |||
|
Maximum Storage Capacity - (with MSA50, SAS HDD) |
|
|
Internal |
2.4TB (16 x 300GB SAS SFF with addition 8 SFF drive cage) |
| External | 6.720TB (20 x 300GB SAS SFF) |
| Total | 4.088TB |
|
|
|
|
Maximum Storage Capacity - (with MSA50, SATA HDD) |
|
|
Internal |
4.0TB (16 x 250GB SAS SFF with additional 8 SFF drive cage) |
| External | 5.0TB (20 x 250GB SAS SFF) |
| Total | 9.0TB |
|
|
|
| Tape and Disk-Based Backup | |||
|
NOTE: For a complete listing of compatible tape and disk-based backup offerings, please visit: www.hp.com/go/connect. |
|
Position Supported |
Controller |
Part Number | |
| HP
StorageWorks SCSI Tape Drives, External LTO-1 Ultrium 232 LTO-2 Ultrium 448 LTO-3 Ultrium 960 LTO-3 Ultrium 920 LTO-4 Ultrium 1760 LTO-4 Ultrium 1840 DAT 40 DAT 72 DAT 160 1U Rack-Mount Kit 3U Rack-Mount Kit | External | HP SC11Xe Host Bus Adapter |
412911-B21 |
| HP StorageWorks USB Tape Drives,
External DAT 40 USB DAT 72 USB DAT 160 USB 1U Rack-Mount Kit | External | USB 2.0 Port | N/A |
| HP
StorageWorks SAS Tape Drives, External DAT 160 SAS LTO-2 Ultrium 448 SAS LTO-3 Ultrium 920 SAS LTO-4 Ultrium 1760 SAS LTO-4 Ultrium 1840 SAS 1U Rack-Mount Kit 3U Rack-Mount Kit |
External | HP Smart Array P212/Zero Memory Controller |
462828-B21 |
| HP
StorageWorks SCSI Tape Automation, External DAT 72x10 Autoloader 1/8 G2 Autoloader MSL2024 MSL4048 MSL8096 MSL6000 |
External | HP SC11Xe Host Bus Adapter |
412911-B21 |
| HP
U320e SCSI Host Bus Adapter NOTE: Recommended for MSL tape libraries. |
AH627A | ||
| HP
StorageWorks SAS Tape Automation, External 1/8 G2 Autoloader MSL2024 MSL4048 MSL8096 |
External | HP Smart Array P212/Zero Memory Controller |
462828-B21 |
| NOTE: Please visit: http://www.hp.com/go/connect for details about minimum SAS controller firmware version and SAS cabling requirements. | |||
| HP
StorageWorks Fibre Tape Automation, External MSL2024 MSL4048 MSL8096 MSL6000 | External | Please consult the EBS connectivity matrix at: http://www.hp.com/go/ebs for detailed connectivity information. |
N/A |
| HP
StorageWorks RDX Removable Disk Backup System RDX160 RDX320 RDX500 | Internal | Half-height
media bay NOTE: RDX160 (AP724A), RDX320 (AP725A), or RDX500 (AP726A) are the required SKUs for mounting inside a HP ProLiant DL380 G6. | N/A |
| HP StorageWorks D2D Backup Systems
D2D120 D2D130 D2D2503i D2D4004i |
External | Embedded Network Controller |
N/A |
|
Содержание технического описания HP ProLiant DL380 Generation 6 |
Power Specifications
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| NOTES: To review typical system power ratings use the HP Power Advisor which is available online located at url: www.hp.com/go/proliant-energy-efficient or www.hp.com/go/hppoweradvisor |
|
Содержание технического описания HP ProLiant DL380 Generation 6 |
Technical Specifications
| System Unit | Dimensions (H
x W x D) (with bezel) | SFF
Drives: 3.38 x 17.54 x 27.25 in (8.59 x 44.55 x 69.22 cm) LFF Drives: 3.38 x 17.54 x 29.25 in (8.59 x 44.55 x 74.30 cm) | ||
| Weight (approximate) | Maximum (all hard drives, power supply, and processor installed) | 60.00 lb (27.27 kg) | ||
| Minimum
(one hard drive, power supply, and processor installed) | 47.18 lb (21.45 kg) | |||
|
Input Requirements (per power supply) | Rated Line Voltage | 100
to 120 VAC 200 to 240 VAC | ||
| Rated Input Current | For
1200 W Power Supply: 10 A (at 100 VAC), 4.9 A (at 200 VAC) For 750 W Power Supply: 8.9 A (at 100 VAC), 4.3 A (at 200 VAC) For 460 W Power Supply: 5.5 A (at 100 VAC), 2.6 A (at 200 VAC) | |||
| Rated Input Frequency | 50 to 60 Hz | |||
| Rated Input Power | For 1200 W Power
Supply: 930 W (at 100 VAC), 1348 W (at 200 VAC) For 750 W Power Supply: 857 W (at 100 VAC), 824 W (at 200 VAC) For 460 W Power Supply: 526 W (at 100 VAC), 505 W (at 200 VAC) | |||
| BTU Rating | Maximum | For
1200 W Power Supply: 3530 BTU/hr (at 100 VAC), 4600 BTU/hr (at 200 VAC) For 750 W Power Supply: 2925 BTU/hr (at 100 VAC), 2812 BTU/hr (at 200 VAC) For 460 W Power Supply: 1794 BTU/hr (at 100 VAC), 1725 BTU/hr (at 200 VAC) | ||
| Power Specifications | NOTE: To review typical system power ratings use the HP Power Advisor which is available online located at url: www.hp.com/go/proliant-energy-efficient or www.hp.com/go/hppoweradvisor | |||
| Power Supply Output (per power supply) | Rated Steady-State
Power | For 1200
W Power Supply: 800 W (at 100 VAC), 900 W (at 120 VAC), 1200 W (at 200 to 240 VAC) For 750 W Power Supply: 750 W (at 100 to 120 VAC), 750 W (at 200 to 240 VAC) For 460 W Power Supply: 460 W (at 100 to 120 VAC), 460 W (at 200 to 240 VAC) | ||
| Maximum Peak Power | For 1200
W Power Supply: 800 W (at 100 VAC), 900 W (at 120 VAC), 1200 W (at 200 to 240 VAC) For 750 W Power Supply: 750 W (at 100 to 120 VAC), 750 W (at 200 to 240 VAC) For 460 W Power Supply: 460 W (at 100 to 120 VAC), 460 W (at 200 to 240 VAC) | |||
| System Inlet Temperature | Operating | 10°
to 35°C (50° to 95°F) at sea level with an altitude derating of 1.0°C
per every 305 m (1.8°F per every 1000 ft) above sea level to a maximum of
3050 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 10°C/hr
(18°F/hr). The upper limit may be limited by the type and number of options
installed. System performance may be reduced if operating with a fan fault or above 30°C (86°F). | ||
| Non-operating | -30° to 60°C (-22° to 140°F). Maximum rate of change is 20°C/hr (36°F/hr). | |||
| Relative Humidity (non-condensing) | Operating | 10 to 90% relative humidity (Rh), 28°C (82.4°F) maximum wet bulb temperature, non-condensing. | ||
| Non-operating | 5 to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb temperature, non-condensing. | |||
| Altitude | Operating | 3050 m (10,000 ft). This value may be limited by the type and number of options installed. Maximum allowable altitude change rate is 457 m/min (1500 ft/min). | ||
| Non-operating | 9144 m (30,000 ft). Maximum allowable altitude change rate is 457 m/min (1500 ft/min). | |||
| Acoustic Noise | Listed
are the declared A-Weighted sound power levels (LWAd) and declared average bystander
position A-Weighted sound pressure levels (LpAm) when the product is operating
in a 23°C ambient environment. Noise emissions were measured in accordance
with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109). NOTE: The Listed sound levels apply to standard shipping configurations. Additional options may result in increased sound levels. | |||
| Idle | 1P SKU | 2P SKU | ||
| LWAd | 4.1
B | 4.7 B | ||
|
LpAm | 22
dBA | 28 dBA | ||
| Operating | 1P
SKU | 2P SKU | ||
| LWAd | 4.1
B | 4.7 B | ||
|
LpAm | 22 dBA | 28 dBA | ||
| Emissions Classification (EMC) | FCC Rating | Class A | ||
| Normative Standards | CISPR 22; EN55022; EN55024; FCC CFR 47, Pt 15; ICES-003; CNS13438; GB9254; K22;K24; EN 61000-3-2; EN 61000-3-3; EN 60950-1; IEC 60950-1 | |||
| NOTE:
Product conformance to cited product specifications is based on sample (type)
testing, evaluation, or assessment. This product or family of products is eligible
to bear the appropriate compliance logos and statements. NOTE: The Listed sound levels apply to standard shipping configurations. Additional options may result in increased sound levels. | ||||
|
| ||||
|
Smart Array P410i Controller |
Dimensions (not including bracket) | Low Profile PCIe Form Factor 7.5 in x 9.5 in x 2.25 in (19.05 cm x 24.13 cm x 5.72 cm) |
| Disk Drive and Enclosure Interface - transfer rate | 3G SAS (Serial Attached SCSI) | |
| 1.5G SATA (Serial ATA) | ||
| SAS Connectors | 2 internal (Mini-SAS) x8 wide port connectors | |
| Cache Memory Speed | DDR2-533MHz with 40 or 72-bit wide bus provides up to 4.2 GB/s maximum bandwidth. | |
| Server Interface | x8 2.5G PCIe 2.0 provides 2GB/s maximum bandwidth | |
| SAS Speed | x8 3G SAS provides 2.4GB/s maximum bandwidth | |
| Cache Memory | 40-bit 256MB ECC protected cache (72-bit 512MB BBWC module upgrades available); transportable with battery-backed upgrade | |
| Logical Drives Supported | Up to 32 logical drives | |
| Maximum Logical Drive Capacity | Greater than 2TB | |
| Host Memory Addressing | 64-bit, supporting greater than 4GB server memory space | |
| RAID Support | RAID 6, 6+0 (Advanced Data Guarding) NOTE: The minimum of 256 MB cache, battery kit, and Smart Array Advanced Pack License Key upgrade is required to enable RAID 6, 6+0 |
|
| RAID 5, 5+0 (Distributed Data
Guarding) NOTE: The 256MB upgrade is required to enable RAID 5 support on the Smart Array P410i. |
||
| RAID 1+0 (Striping & Mirroring) | ||
| RAID 0 (Striping) | ||
| Upgradeable Firmware | Upgradeable Firmware with Recovery ROM feature | |
|
|
||
| HP NC382i Dual Port Multifunction Gigabit Server Adapters | Network Interface | 10Base-T/100Base-TX/1000Base-TX | |
| Compatibility | EEE 802.3 10Base-T | ||
| IEEE 802.3ab 1000Base-T | |||
| IEEE 802.3u 100Base-TX | |||
| IEEE 802.3ad 1000Base-TX | |||
| IEEE 802.1p 100Base-TX | |||
| IEEE 802.1q 100Base-TX | |||
| Data Transfer Method | PCI Express, four lanes (x4) | ||
| Network Transfer Rate | 10Base-T (Half-Duplex) | 10 Mb/s | |
| 10Base-T (Full-Duplex) | 20 Mb/s | ||
| 100Base-TX (Half-Duplex) | 100 Mb/s | ||
| 100Base-TX (Full-Duplex) | 200 Mb/s | ||
| 1000Base-TX (Half and Full-Duplex) | 2000Mb/s | ||
| Connector | Two RJ-45 | ||
| Cable Support | 10Base-T | Categories
3, 4 or 5 UTP; up to 328 ft (100 m) | |
| 100Base-TX | Category
5 or higher UTP; up to 328 ft (100 m) | ||
| 1000BaseTX | Category
5 or higher UTP; up to 328 ft (100 m) | ||
|
| |||
| Environment-friendly Products and Approach | End-of-life Management and Recycling |
Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling
programs in many geographic areas. For trade-in information, please go
to: http://www.hp.com/go/green.
To recycle your product, please go to: http://www.hp.com/go/green
or contact your nearest HP sales office. Products returned to HP will
be recycled, recovered or disposed of in a responsible manner. |
| | ||
|
© Copyright 2009 Hewlett-Packard Development Company,
L.P. |
 DA-13234 6 - Version 6 - May 21, 2009
Вопросы и ответы
Оцените новый конфигуратор серверов
Доcтаточно просто нажать на выбранный вами пункт!Перейти к списку доступных для конфигурирования моделей
Удобно и адекватные цены
Удобно, но цены кусаются
Использую для сравнения, но покупать не буду
Собираю конфигурации на других сайтах
Хотелось бы видеть цены сразу
Акции
Компания Server Unit предлагает позиции своего склада по сниженным ценам.
Новости
- Новый сертификат от APC
- Новинка: Dell PowerEdge C6145
- Новая услуга "Сервер Эксперт"
- Eset начинает бета-тестирование NOD32 для Lotus Domino
- StorСenter ix2 Network Storage от Iomega
- Наши клиенты: ОАО "Гайский ГОК"
- Самый тонкий в мире ультрабук
- Компания Seagate приобрела подразделение у Samsung
- 75 новых ультрабуков в 2012 году
- Наши новые клиенты: ОАО ГАК "ОБОРОНПРОМКОМПЛЕКС"