HP ProLiant DL360 Generation 6
Компания Sever Unit представляет полное описание HP ProLiant DL360 Generation 6. В мануале вы найдете подробные технические характеристики HP ProLiant DL360 Generation 6, а также дополнительные опции для HP ProLiant DL360 Generation 6. По вопросам приобретения HP ProLiant DL360 Generation 6 обращайтесь в компанию Server Unit по тел.: +7 (495) 665-65-25, market@server-unit.ru|
Содержание технического описания HP ProLiant DL360 Generation 6 |
Overview
|
HP ProLiant DL360 Generation 6 (G6) | |||
|
| ![]() | ||
| Front View: | Rear View: | ||
| 1. | Hood Cover | 1. | PCI Express expansion slot 1, low-profile, half-length |
| 2. | Up to two Intel Quad-Core or Dual-Core Xeon™ processors) | 2. | PCI Express expansion slot 2 full height full length x16 (16, 8, 4, 2, 1), 75W +EXT 75W (optional PCI-X support) |
| 3. | Video Connector | ||
| 4. | Slide-out System Insight Display | 3. | Power supply bay 1 (populated) |
| 5. | Removable fans for easy serviceability | 4. | Power supply bay 2 |
| 6. | Eighteen DIMM slots: DDR3 Registered (RDIMM) or Unbuffered (UDIMM) memory | 5. | iLO 2 NIC connector |
| 6. | Serial connector | ||
| 7. | Redundant Hot Plug Power Supplies (upgradeable option) | 7. | Video connector |
| 8. | 2 PCI-E Slots | 8. | Mouse connector |
| 9. | Keyboard connector | ||
| 10. | NIC 2 connector | ||
| 11. | NIC 1 connector | ||
| 12. | USB connector | ||
| 13. | USB connector | ||
| | |||
| At A Glance |
| Combining improved 1U compute performance, smart power and cooling management with infrastructure management tools and essential fault tolerance, the HP ProLiant DL360 G6 is optimized for space constrained installations. Latest Intel 5500 Series Xeon® Processors (Quad-Core and Dual-Core), with choice of DDR3 Registered or Unbuffered DIMMs, Serial Attached SCSI (SAS) and PCI Express Gen2 technology provide a high performance system, ideal for the full range of scale out applications. What's
more, the DL360 G6 steps up the fault tolerant in an ultra-dense platform with
redundant power, redundant fans, mirrored memory and embedded RAID capability.
|
|
Содержание технического описания HP ProLiant DL360 Generation 6 |
Standard Features
| NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section. | |
| Processor One of the following depending on Model | Quad-Core Processors |
| Intel® Xeon® Processor X5570 (2.93 GHz,8MB L3 Cache, 95 Watts, DDR3-1333, HT Turbo 2/2/3/3) | |
| Intel® Xeon® Processor X5560 (2.80 GHz, 8MB L3 Cache, 95 Watts, DDR3-1333, HT Turbo 2/2/3/3) | |
| Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95 Watts, DDR3-1333, HT Turbo 2/2/3/3) | |
| Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80 Watts, DDR3-1066, HT Turbo 1/1/2/2) | |
| Intel® Xeon® Processor E5530 (2.40 GHz, 8MB L3 Cache, 80 Watts, DDR3-1066, HT Turbo 1/1/2/2) | |
| Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60 Watts, DDR3-1066, HT Turbo 1/1/2/2) | |
| Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 80 Watts, DDR3-1066, HT Turbo 1/1/2/2) | |
| Intel® Xeon® Processor L5506 (2.13 GHz, 4MB L3 Cache, 60 Watts, DDR3-800) | |
| Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80 Watts, DDR3-800) | |
| Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80 Watts, DDR3-800) | |
| Dual-Core Processors | |
| Intel® Xeon® Processor E5502 (1.86 GHz, 4MB L3 Cache, 80 Watts, DDR3-800) | |
| NOTE:
Up to 2 processors supported. Performance Model configurations include two processors. NOTE: HT indicates that the processor model supports Intel® /Hyper-Threading Technology NOTE: Turbo indicates the maximum potential frequency increment when using Intel® Turbo Boost Technology, with 4,3,2 and 1 cores active. NOTE: DDR3 speed is the maximum memory speed of the processor. Actual memory speed may depend on the quantity and type of DIMMs installed. NOTE: For the Intel 5500 Series, the letter preceding the model number indicated the performance/wattage of the processor. "X" denotes High Performance/Wattage; "E" denotes Enterprise Performance/Wattage (Mainstream); and "L" denotes Lower Wattage. | |
| | |
| Cache
Memory One of the following depending on Model | 8MB
(1 x 8MB) Level 3 cache NOTE: All processor models except for those identified below. |
| 4MB
(1 x 4MB) Level 3 cache NOTE: For processors E5506/L5506/E5504/E5502. | |
|
| |
| Chipset | Intel® 5520 Chipset NOTE: For more information regarding Intel® chipsets, please see the following URL: http://www.intel.com/products/server/chipsets/. |
|
|
|
| Memory Protection | Advanced ECC (multi-bit error protection) |
| Mirroring mode | |
| Lock-step mode | |
| | |
| Memory | Type | DDR3 Registered (RDIMM) or Unbuffered (UDIMM) |
| Standard (Performance Models) | 12 GB (6 x 2 GB) RDIMM | |
| Standard (Base Models) | 6 GB (3 x 2 GB) RDIMM | |
| Standard (Entry Model) | 4 GB (2 x 2 GB) RDIMM | |
| Standard (High Efficiency Model) | 4 GB (2 x 2GB) UDIMM | |
| Maximum (RDIMM) | 144 GB (18 x 8 GB) for Registered Memory configurations | |
| Maximum (UDIMM) | 24 GB (12 x 2 GB) for Unbuffered Memory configurations | |
| NOTE:
Depending on the memory configuration and processor model, the memory speed
may run at 1333MHz, 1066MHz, or 800MHz. Please see the Online Memory Configuration
Tool at: www.hp.com/go/ddr3memory-configurator. NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient. |
||
| DDR3 memory options part number decoder | ||
![]() | ||
| | ||
| Network Controller | One HP NC382i Dual Port Multifunction Gigabit Server Adapter (two ports total) with TCP/IP Offload Engine, including support for Accelerated iSCSI |
|
| |
| Expansion Slots |
Expansion Slots #
|
Technology
|
Bus
Width** |
Connector Width
|
Bus Number*
|
Form Factor
|
Notes
|
|
1
|
PCI-e
|
x8
|
x8
|
4
|
Low profile slot
|
||
| 2 | PCI-e | x16 | x16 | 7 | Full length, full height slot | ||
|
2
|
PCI-X
(133 MHz, 3.3 Voltage) |
64-bit
|
x8
|
7
|
|||
| * Default
bus assignment (in decimal). Inserting cards with PCI bridges may alter
the actual bus assignment number ** Indicates the number of physical electrical lanes running to the connector. |
|||||||
|
|
|||||||
| Storage
Controller One of the following depending on Model | Entry Models | HP Smart Array P410i/Zero Memory Controller (RAID 0/1/1+0) |
| Base Models | HP Smart Array P410i/256 MB Controller (RAID 0/1/1+0/5/5+0) | |
| Performance Models | HP Smart Array P410i/512 MB BBWC Controller (RAID 0/1/1+0/5/5+0) | |
| High Efficiency Models | HP Smart Array P410i/Zero Memory Controller (RAID 0/1/1+0) | |
| Available upgrades: 256MB, 512MB with BBWC, Battery kit upgrade (for BBWC), and Smart Array Advanced Pack (SAAP) | ||
| | ||
| Storage | Diskette Drive | None Standard |
| Optical Drive One of the following depending on Model |
None Standard | |
| Optional DVD-ROM, DVD-RW or Slimline floppy drive | ||
| Hard Drives | None Standard | |
| Drive Bays | Up to 8 Small Form Factor drive bays total | |
| NOTE: 4 bays standard in Entry / Base & High Efficiency models, with optional upgrade of 4 additional bays with the SFF HD Backplane Kit (516966-B21) | ||
|
|
||
| Maximum Internal Storage Type | Hot Plug SAS | 2.4TB | 8 x 300GB SAS |
| Hot Plug SATA | 2.0TB | 8 x 250GB SATA | |
| | |||
| Interfaces | Keyboard | 1 |
| Mouse | 1 | |
| Serial | 1 | |
| Video | 1 | |
| Network RJ-45 | 2 | |
| iLO 2 remote management port |
1 | |
| SD slot | 1 | |
| USB 2.0 Ports | 4 total: 2 rear, 1 front, 1
internal NOTE: Please see the following URL for additional information regarding USB support: http://h18004.www1.hp.com/products/servers/platforms/usb-support.html. |
|
|
|
||
| Graphics |
Integrated ATI ES1000, 32MB video standard
NOTE: Maximum resolution available via iLO 2 remote console is 1280 x 1024. |
|
|
|
| Form Factor | 1U Rack form factor (1.75"), less than 28 inches (70.5 cm) deep |
|
|
|
| HP Insight Control Environment Suite |
HP Insight Control suite delivers essential management, including proactive
health management, lights out remote control, optimization of power usage, rapid
server deployment, performance analysis, patch management and virtual machine
management.
Additional Insight Software standalone products and management tools included on the Insight Software media kit can be installed manually
NOTE:
HP Insight Server Migration software for ProLiant can be installed from the HP
Insight Server Migration software for ProLiant CD included in the Insight Software
media kit |
| | |
| ProLiant Onboard Administrator | HP
ProLiant Onboard Administrator (powered by the HP Integrated Lights-Out 2 management
processor) simplifies server setup, health monitoring, power and thermal control,
and lights-out remote administration of ProLiant ML, DL, and BL servers. HP ProLiant
Onboard Administrator functions without additional software, and can be accessed
from any location via a web browser. It works hand-in-hand with HP Systems Insight
Manager, Insight Control, and Insight Dynamics - VSE suite helping customers unlock
the value of the ProLiant platform and deliver the highest possible quality of
IT service to the business.
Enable extended remote administration features of HP ProLiant Onboard Administrator with Integrated Lights-Out 2 Advanced. |
|
| |
| Server Management Stand Alone Software Products | HP Systems Insight Manager | HP Systems Insight Manager (HP
SIM) provides a unified, secure and extensible standards-based environment
to centrally manage servers, storage and other infrastructure devices, (both
HP and non-HP) across multiple operating system platforms. For additional information, please see: www.hp.com/go/insight |
| HP Insight Rapid Deployment software | Insight Rapid Deployment software extends HP Systems Insight Manager with a complete deployment solution for HP ProLiant servers. RDP provides a central location to configure server hardware, deploy Windows, Linux and VMware ESX operating environments and install HP ProLiant Support Pack drivers using images and scripted profiles. For more information, visit: http://www.hp.com/go/rdp. | |
| HP Insight Server Migration software for ProLiant |
Upgrading, replacing, or virtualizing your existing server? Effortlessly transition to new virtual or physical HP ProLiant servers or BladeSystem with automated, accurate and affordable migration of OS, application and data. HP Insight Server Migration software for ProLiant automates the manual processes required for migrating servers between physical or virtual platforms, whether migrating to VMware or Microsoft virtual machines. HP Insight Server Migration software for ProLiant allows all of the following migrations:
NOTE: For more information, visit: http://www.hp.com/go/migrate. |
|
| HP Insight Dynamics - VSE suite for ProLiant | The HP Insight Dynamics - VSE
suite for ProLiant is advanced infrastructure management software that allows
you to analyze and optimize your adaptive infrastructure to manage physical
and virtual resources in the same way. HP Insight Dynamics - VSE gives you
a powerful toolkit to accelerate complex technology projects and simplify
daily operations. It enables you to plan capacity and power continuously,
balance across physical and virtual resources, ensure cost-effective high
availability and provision infrastructure consistently. HP Insight Orchestration, an optional extension to Insight Dynamics - VSE, enables IT organizations to provision infrastructure consistently and automatically from pools of shared resources using a self-service portal. Resources provisioned can range from a single virtual machine to complex multi-tier environments and their associated physical and virtual resource requirements. HP Insight Recovery, also an optional extension for Insight Dynamics - VSE, enables cost-effective disaster recovery for physical and virtual environments. Application environments can be reactivated in minutes with the touch of a button to a remote location NOTE: For more information, visit: http://www.hp.com/go/insightdynamics, http://www.hp.com/go/insightorchestration, http://www.hp.com/go/insightrecovery |
|
| HP Integrated Lights-Out (iLO 2) Advanced Pack | Unlocks the full capabilities of the HP ProLiant Onboard Administrator with comprehensive remote control including Virtual KVM remote graphical console, power management capabilities such as power measurement, regulation, and capping, new iLO Text Console, automatic and on-demand video recording of server events, global team collaboration for up to four remote users, virtual media (floppy, CD/DVD, USB key), virtual folders, and enterprise security (directory services and two-factor authentication). For additional information, please see: www.hp.com/go/iLO | |
| HP Insight Power Manager software (IPM) | Upgrades the single-server remote management capabilities of iLO Select/Advanced to include centralized reporting and policy-based management of power consumption and thermal output provided by the Insight Power Manager software. IPM unifies all of this functionality within a single user interface - HP Systems Insight Manager. For additional information, please see: www.hp.com/go/ipm | |
| NOTE: Flexible and volume quantity license kits are available for Value Packs. Refer to: http://www.hp.com/servers/proliantessentials or the various Value Pack product QuickSpecs for more information. | ||
|
|
||
| Core Infrastructure Management | HP Foundation Pack |
Managing the growing number of servers can be complex and expensive for your
organization. IT managers need to address changing business needs with tools that
meet the challenges of managing today's complex Datacenters.
SmartStart
version supported (minimum): SmartStart 8.20. |
| Insight Management Providers (WBEM) | The HP Insight
Management WBEM Providers leverage the rich set of base-level instrumentation
provided by the system management controllers and drivers, I/O controllers and
drivers, and system firmware interfaces delivering in-depth hardware management,
including hardware inventory data, system state, and event notifications.
The
Insight Management Providers are included on ProLiant Support Packs. | |
| Insight Management Agents (SNMP) | The Insight Management
Agents should be installed on all HP servers to present system instrumentation,
health and configuration information into HP Systems Insight Manager and the HP
System Management Homepage. The HP System Management Homepage aggregates systems
data from Insight Management Agents and other HP management tools, providing a
consolidated browser-based interface for managing individual servers. | |
| Subscriber's Choice | Subscriber's
Choice Driver and Support Alerts/Notifications is a web-based email subscription
service that provides software and driver change notifications for ProLiant products.
Sign up at: http://www.hp.com/go/subscriberschoice and customize your profile to receive various new alerts as they become available, on a weekly or monthly basis. | |
| ProLiant Support Packs and ROMPaq, software | The latest software, drivers, and firmware fully optimized and tested for your ProLiant server and options, available through ProLiant Support Packs the Insight Rapid Deployment software, SmartStart or downloaded from software and drivers download pages website at: http://www.hp.com/go/support. | |
| | ||
| HP Serviceguard for Linux (SGLX) |
HP Serviceguard for Linux provides high availability clustering for Linux
applications running on HP Integrity, HP ProLiant and other supported
industry-standard servers. Serviceguard for Linux reduces planned and
unplanned downtime and delivers efficient, continuous access to business-critical
applications - with all of the enterprise features you expect from HP.
NOTE: For additional information including
software and server support on HP Serviceguard for Linux, visit: http://www.hp.com/go/sglx
or see the HP Serviceguard for Linux QuickSpecs. |
| | |
| Industry Standard Compliance | ACPI 2.0b Compliant PCI 2.2 Compliant WOL Support Microsoft® Logo certifications PXE Support USB 1.1 and 2.0 Compliant SMBIOS 2.6.1 |
| | |
| Security | Power-on password Keyboard password Diskette drive control Diskette boot control QuickLock, Network Server Mode Removable CD and Diskette Drive Assembly Serial interface control Administrator's password Integrated Lights-Out has 12 customizable user accounts and SSL encryption Integrated Lights-Out can be disabled via a Global Setting iLO Advance Pack supports directory services integration and two-factor authentication |
|
|
|
| Security Trusted Platform Module | The
TPM (Trusted Platform Module) is a microcontroller chip that can securely store
artifacts used to authenticate the server platform. These artifacts can include
passwords, certificates and encryption keys. Windows® BitLocker™ Drive
Encryption (BitLocker) is a data protection feature available in Windows Server®
2008. BitLocker leverages the enhanced security capabilities of a Trusted Platform
Module (TPM) version 1.2. The TPM works with BitLocker to help protect user data
and to ensure that a server running Windows Server 2008 has not been tampered
with while the system was offline. For more information about TPM, including a white paper, go to www.hp.com/go/TPM NOTE: ProLiant OS pre-installed units will come with the partition required for TPM deployment. NOTE: The TPM key is unique to every TPM deployed server and must be retained. Misplacing or losing the key could result in data loss. |
|
| |
| Server Power Cords | High voltage power
cord ships standard with all part numbers. Localized cables included with geographic
specific models in other world regions. NOTE: ProLiant DL servers no longer ship standard with NEMA power cords (187335-001) that allow connection to 110V US wall outlets in a home or office. ProLiant DL servers are primarily connected to PDU's in data center racks so they now ship standard with only a PDU power cord (416151-B21). If a user wishes to power a ProLiant DL server using a 110V receptacle (NEMA-15), the above NEMA power cord must be ordered separately. |
|
| |
| UPS Power Cord Matrix | Please see the UPS and PDU cable
matrix that lists cable descriptions, requirements, and specifications for
UPS and PDU units: http://h18004.www1.hp.com/products/servers/proliantstorage/power-protection/index.html |
| | |
| Power Supply | HP has a new design for ProLiant
power. The new Common Slot Power Supply bay. This design provides the customer
with commonality in power supplies across multiple platforms to save on
the cost of spares and allows HP to offer multiple power solutions to fit
the customers' needs. Many HP ProLiant Servers come with Common Slot, High
Efficiency and Right-Size Power Supplies. Common Slot (CS) designates commonality
of the power supply across multiple ProLiant servers. HP's new Common Slot
power supplies are designed for highest efficiency to provide power efficiency
without degrading performance of the ProLiant. Power Supplies will have
efficiency ratings up to 92%. There are three Right Size power options available,
depending on the configuration of your server. To make sure you select the
correct power supply to meet your configuration, we suggest that you use
the HP Power Advisor to decide the "Right-Size" for your configuration.
All HP Common Slot power sources are UL, CE Mark Compliant, Hot Plug and
Redundant. The HP Power Advisor is located at: www.hp.com/go/proliant-energy-efficient or www.hp.com/go/hppoweradvisor |
| | |
| Common Slot Power Supply | It is highly recommended that you use the HP Power Advisor in defining the "Right-Size" power supply for your needs. HP offers multiple Power Supply Options:
HP's ProLiant
Common Slot Power supplies (460W & 750W) meet multiple Energy Efficiency Initiatives.
Climate Savers Computing Initiative GOLD, 80PLUS GOLD and plans on offering models
that meet the Energy Star for Server requirements when they are published. |
|
| |
| System Fans | 3 fans ship standard in
1 processor models 4 fans ship standard in 2 processor models N+1 fan redundancy standard NOTE: The processor option kit contains the additional 2 fans, when upgrading the 1 processor models. A Fan Option kit can also be purchased separately for use with PCI Graphics card upgrades. |
| | |
| Required Cabling | For required cabling information, refer to the Web site at: http://h18000.www1.hp.com/products/servers/proliantdl360/. |
|
|
|
| Operating Systems and Virtualization Software Support for ProLiant Servers |
Microsoft
Windows Server |
|
|
|
| Rack Airflow Requirements |
Rack 10000 series Cabinets
CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage. |
| NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the server, or to the server documentation located in the Support section at the following URL: www.hp.com/servers/dl360. | |
|
|
|
| Rack Kit |
The HP ProLiant DL360 quick deploy rail system provides tool-free support for racks with square or round mounting holes (including Compaq/HP 7000*, 9000, 10000 and HP series) with an adjustment range to fit a rack depth of 21.25" to 37.75". |
|
| |
| Telco Rack Support |
HP ProLiant DL360 Telco Rack Kit: |
|
|
|
| Factory Express Portfolio for Servers and Storage |
HP Factory Express offers configuration, customization, integration and
deployment services for HP servers and storage products. Customers can
choose how their factory solutions are built, tested, integrated, shipped
and deployed. |
| | |
| HP Enterprise Configurator | The HP eConfigure-Enterprise Configurator now provides factory default racking for our HP hardware portfolio. This approach is aligned with our strategic direction to meet the needs and expectations of our valued customers. If you require "custom" rack configuration, please contact HP's Customer Business Center or an Authorized Partner for assistance. http://www.hp.com/products/configurator |
| | |
| Service and Support |
HP Care Pack services provide total care and support expertise with
committed response designed to meet your IT and business needs.
Enhanced Service - optimize service level to increase IT performance and availability.
Refer to the information on "Installation & Start-Up" for
service on ProLiant server and Microsoft or Linux O/S per the Customer
Description and/or Data Sheet; to be delivered on a scheduled basis 8am-5pm,
M-F, excluding HP holidays. |
|
Содержание технического описания HP ProLiant DL360 Generation 6 |
Models
|
NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section. | ||
|
HP DL360 G6 Performance Models | Processor(s) | (2) Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95 Watts, DDR3-1333, HT Turbo 2/2/3/3) |
| Cache Memory | 8MB (1 x 8MB) Level 3 cache | |
| Memory | 12 GB (6 x 2 GB) PC3-10600R (DDR3-1333) Registered DIMMs | |
| Network Controller | HP NC382i Dual Port Multifunction Gigabit Server Adapter | |
| Storage Controller | HP Smart Array P410i/512MB with BBWC | |
| Hard Drive | None ship standard | |
| Internal Storage | 8 SFF SAS/SATA HDD Bays | |
| Optical Drive | None ship standard | |
| PCI-Express Slots | PCI-e Gen2 (1 FH/FL, 1 HH/HL) PCI-X support optional in the FH/FL slot | |
| Power Supply | Two 460W Hot Plug Power Supplies, redundant | |
| Fans | 4 total (3 fans in 1 Processor Models, 1 additional fans with second processor) redundancy standard | |
| Form Factor | 1U Rack form factor (1.75"), less than 28 inches (70.5 cm) deep | |
|
| ||
|
HP DL360 G6 Performance Models with ICE standard |
Processor(s) | (2) Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3) |
| Cache Memory | 8MB (1 x 8MB) Level 3 cache | |
| Memory | 12 GB (6 x 2 GB) PC3-10600R (DDR3-1333) Registered DIMMs | |
| Network Controller | Two HP NC382i Dual Port Multifunction Gigabit Server Adapters | |
| Storage Controller | HP Smart Array P410i/512MB with BBWC | |
| Hard Drive | None ship standard | |
| Internal Storage | 8 SFF SAS/SATA HDD Bays | |
| Optical Drive | None ship standard | |
| Power Supply | Two 460W Hot Plug Power Supplies, redundant | |
| Fans | 4 total (3 fans in 1 Processor Models, 1 additional fans with second processor) redundancy standard | |
| Insight Control Environment (ICE) | ICE 24x7 support | |
| Form Factor | 1U Rack form factor (1.75"), less than 28 inches (70.5 cm) deep | |
|
| ||
|
HP DL360 G6 Base Models | Processor(s) One of the following depending on Model | (1)
Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80 Watts, DDR3-1066,
HT Turbo 1/1/2/2) (1) Intel® Xeon® Processor E5530 (2.40 GHz, 8MB L3 Cache, 80 Watts, DDR3-1066, HT Turbo 1/1/2/2) |
| Cache Memory | 8MB (1 x 8MB) Level 3 cache | |
| Memory | 6 GB (3 x 2 GB) PC3-10600R (DDR3-1333) Registered DIMMs | |
| Network Controller | HP NC382i Dual Port Multifunction Gigabit Server Adapter | |
| Storage Controller | HP Smart Array P410i/256MB Controller | |
| Hard Drive | None ship standard | |
| Internal Storage | 4 SFF SAS/SATA HDD Bays (with optional 4SFF HDD upgrade) | |
| Optical Drive | One Multi-Media bay standard (not available with 4SFF HDD upgrade) | |
| PCI-Express Slots | PCI-e Gen2 (1 FH/FL, 1 HH/HL) PCI-X support optional in the FH/FL slot | |
| Power Supply | One 460W Hot Plug Power Supply | |
| Fans | 3 total (3 fans in 1 Processor Models, 1 additional fans with 2 Processor Model) redundancy standard | |
| Form Factor | 1U Rack form factor (1.75"), less than 28 inches (70.5 cm) deep | |
|
| ||
|
HP DL360 G6 Efficiency Models | Processor(s) | (1) Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 60 Watts, DDR3-1066, HT Turbo 1/1/2/2) |
| Cache Memory | 8MB (1 x 8MB) Level 3 cache | |
| Memory | 4 GB (2 x 2 GB) PC3-10600E (DDR3-1333) Unbuffered DIMMs | |
| Network Controller | HP NC382i Dual Port Multifunction Gigabit Server Adapter | |
| Storage Controller | HP Smart Array P410i/Zero Memory Controller | |
| Hard Drive | None ship standard | |
| Internal Storage | 4 SFF SAS/SATA HDD Bays (with optional 4SFF HDD upgrade) | |
| Optical Drive | One Multi-Media bay standard (not available with 4SFF HDD upgrade) | |
| PCI-Express Slots | PCI-e Gen2 (1 FH/FL, 1 HH/HL) PCI-X support optional in the FH/FL slot | |
| Power Supply | One 460W Hot Plug Power Supply | |
| Fans | 3 total (3 fans in 1 Processor Models, 1 additional fans with 2 Processor Model) redundancy standard | |
| Form Factor | 1U Rack form factor (1.75"), less than 28 inches (70.5 cm) deep | |
|
| ||
|
HP DL360 G6 Entry Model | Processor(s) | (1) Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80 Watts, DDR3-800) |
| Cache Memory | 4MB (1 x 4MB) Level 3 cache | |
| Memory | 4 GB (2 x 2 GB) PC3-10600R (DDR3-1333) Registered DIMMs | |
| Network Controller | HP NC382i Dual Port Multifunction Gigabit Server Adapter | |
| Storage Controller | HP Smart Array P410i/Zero Memory Controller | |
| Hard Drive | None ship standard | |
| Internal Storage | 4 SFF SAS/SATA HDD Bays (with optional 4SFF HDD upgrade) | |
| Optical Drive | One Multi-Media bay standard (not available with 4SFF HDD upgrade) | |
| PCI-Express Slots | PCI-e Gen2 (1 FH/FL, 1 HH/HL) PCI-X support optional in the FH/FL slot | |
| Power Supply | One 460W Hot Plug Power Supply | |
| Fans | 3 total (3 fans in 1 Processor Models, 1 additional fans with 2 Processor Model) redundancy standard | |
| Form Factor | 1U Rack form factor (1.75"), less than 28 inches (70.5 cm) deep | |
|
| ||
| Country Code Key | XX=00 | US |
| XX=20 | Brazil | |
| XX=29 | Japan | |
| XX=37 | APD | |
| XX=42 | EURO | |
| XX=AA | PRC |
|
Содержание технического описания HP ProLiant DL360 Generation 6 |
Configuration Information - Factory Integrated Models
|
NOTE: This section lists some of the steps required to configure a Factory
Integrated Model. To ensure only valid configurations are ordered, HP recommends
the use of an HP approved configurator. Contact your local sales representative
for information on CTO product offerings and requirements. | ||
| Step 1: Base Configuration (choose one of the following configurable models) | ||
| Models | HP ProLiant DL360 G6 Rack CTO Chassis | |
| Factory Integrated Model ships with: | ||
| HP NC382i Dual
Port Multifunction Gigabit Server Adapter | 484184-B21 | |
| | ||
| Step 2: Choose Required Options (only one of the following from each list unless otherwise noted) | ||
| Processors | Quad-Core Processors | |
| Intel® Xeon® Processor X5570 (2.93 GHz,8MB L3 Cache, 95 Watts, DDR3-1333, HT Turbo 2/2/3/3) | 507674-L21 | |
| Intel® Xeon® Processor X5560 (2.80 GHz, 8MB L3 Cache, 95 Watts, DDR3-1333, HT Turbo 2/2/3/3) |
507676-L21 | |
| Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95 Watts, DDR3-1333, HT Turbo 2/2/3/3) | 505878-L21 | |
| Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80 Watts, DDR3-1066, HT Turbo 1/1/2/2) |
505880-L21 | |
| Intel® Xeon® Processor E5530 (2.40 GHz, 8MB L3 Cache, 80 Watts, DDR3-1066, HT Turbo 1/1/2/2) | 505882-L21 | |
| Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 60 Watts, DDR3-1066, HT Turbo 1/1/2/2) |
507680-L21 | |
| Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 80 Watts, DDR3-1066, HT Turbo 1/1/2/2) | 505884-L21 | |
| Intel® Xeon® Processor L5506 (2.13 GHz, 4MB L3 Cache, 60 Watts, DDR3-800) |
507678-L21
| |
| Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80 Watts, DDR3-800) | 505886-L21 | |
| Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80 Watts, DDR3-800) |
507682-L21 | |
| Dual-Core Processors | ||
| Intel® Xeon® Processor E5502 (1.86 GHz, 4MB L3 Cache, 80 Watts, DDR3-800) | 507663-L21 | |
| NOTE:
Up to 2 processors supported. Performance Model configurations include two processors. NOTE: HT indicates that the processor model supports Intel® /Hyper-Threading Technology NOTE: Turbo indicates the maximum potential frequency increment when using Intel® Turbo Boost Technology, with 4,3,2 and 1 cores active. NOTE: DDR3 speed is the maximum memory speed of the processor. Actual memory speed may depend on the quantity and type of DIMMs installed. NOTE: For the Intel 5500 Series, the letter preceding the model number indicated the performance/wattage of the processor. "X" denotes High Performance/Wattage; "E" denotes Enterprise Performance/Wattage (Mainstream); and "L" denotes Lower Wattage. | ||
| Base Memory | Registered DIMMs (RDIMMs) | |
| HP 2GB 2Rx8 PC3-10600R-9 Kit |
500656-B21 | |
| HP 4GB 2Rx4 PC3-10600R-9 Kit |
500658-B21 | |
| HP 4GB 4Rx8 PC3-8500R-7 LP Kit |
500660-B21 | |
| HP 8GB 2Rx4 PC3-8500R-7 Kit |
516423-B21 | |
| HP 8GB 2Rx4 PC3-10600R-9 Kit | 500662-B21 | |
| Unbuffered with ECC DIMMs (UDIMMs) | ||
| HP 1GB 1Rx8 PC3-10600E-9 Kit | 500668-B21 | |
| HP 2GB 2Rx8 PC3-10600E-9 Kit | 500670-B21 | |
| NOTE:
All DDR3 memory option kits consist of one DIMM per kit. For detailed memory configuration
rules and guidelines, please use the Online DDR3 Memory Configuration Tool: www.hp.com/go/ddr3memory-configurator. NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient | ||
| Power Supplies | NOTE:
Many HP ProLiant Servers now offer new power options, including Common Slot Power
Supplies. These power supplies come in multiple power ratings and higher efficiency
levels to offer the Right Size solution to fit your configuration. This provides
improved power delivery and the advantage of reclaiming lost power. Prior to making
a power supply selection it is "highly recommended" that the "HP
Power Advisor" is run to determine the right size power supply for your server
configuration. The HP Power Advisor is located at "www.hp.com/go/proliant-energy-efficient"
or www.hp.com/go/hppoweradvisor | |
| HP 460W CS HE Power Supply Kit | 503296-B21 | |
| HP 750W CS HE Power
Supply Kit | 512327-B21 | |
| HP 1200W CS HE Power
Supply Kit | 500172-B21 | |
| HP
1200W-48V DC Common Slot Power Supply NOTE: DC power supplies contain a -48V DC power cord designed for in rack DC power rectifiers | 437573-B21 | |
| NOTE: Option Kits contain optional power supply, an IEC power cable and PDU IEC cables. | ||
| | ||
| Step 3: Choose Additional Factory Integratable Options | ||
| Storage Controller(s) | NOTE:
If Additional Memory Cache Module or Controller is Required please pick one of
the following: | |
HP
256 MB P-series cache module FIO | 534108-B21 | |
| HP
256MB P-Series Cache Upgrade | 462968-B21 | |
| HP
650mAh P-Series Battery for BBWC | 462969-B21 | |
| HP 512MB P-Series Cache w/BBWC | 462967-B21 | |
| Integrated hypervisor (iHV) | NOTE: HP VMware ESXi free download from www.software.hp.com - select Virtualization | |
| HP VMware 3i Enterprise
2p Lic SW NOTE: For additional information and options kits, please see the QuickSpecs at: www.hp.com/go/vmware. | 430341-B21 | |
| NOTE:
HP XenServer Select Edition free Download from: http://h20392.www2.hp.com/portal/swdepot/displayProductInfo.do? productNumber=HPXS |
| |
| HP
Essentials -XenServer Platinum Nm Lic |
530753-B21 | |
| HP
ProLiant Virtual Console Full License |
508293-B21 | |
| XenServer
HP Ent Upg iSW Lic |
464676-B21 | |
HP
Citrix Essentials for XenServer Enterprise Edition | 508294-B21 | |
| Performance Packs | The HP ProLiant DL360 G6 performance packs are necessary to configure a HP ProLiant DL360 G6 Performance Model. HP ProLiant DL360 G6 Performance model includes the latest performance technologies and enterprise class availability features pre-installed for convenience and value. The performance pack includes a 2nd processor, redundant 460w power supplies, Smart Array P410i Controller with 512MB of BBWC: | |
| HP DL360G6 X5550 HPM FIO Perf Pack |
507937-B21 | |
|
| ||
| Step 4: Choose Additional Options for Factory Integration |
| NOTE: For additional options, please refer to the "Core Options" and "Additional Options" sections below. |
|
Содержание технического описания HP ProLiant DL360 Generation 6 |
Core Options
| NOTE: Some options may not be factory integratable. Contact your local sales representative for additional information. | ||
| HP
ProLiant DL360 G6 Unique Options | Intel® Xeon® Processor X5570 (2.93 GHz,8MB L3 Cache, 95 Watts, DDR3-1333, HT Turbo 2/2/3/3) | 507674-B21 |
| Intel® Xeon® Processor X5560 (2.80 GHz, 8MB L3 Cache, 95 Watts, DDR3-1333, HT Turbo 2/2/3/3) | 507676-B21 | |
| Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95 Watts, DDR3-1333, HT Turbo 2/2/3/3) | 505878-B21 | |
| Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80 Watts, DDR3-1066, HT Turbo 1/1/2/2) | 505880-B21 | |
| Intel® Xeon® Processor E5530 (2.40 GHz, 8MB L3 Cache, 80 Watts, DDR3-1066, HT Turbo 1/1/2/2) | 505882-B21 | |
| Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 60 Watts, DDR3-1066, HT Turbo 1/1/2/2) | 507680-B21 | |
| Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 80 Watts, DDR3-1066, HT Turbo 1/1/2/2) | 505884-B21 | |
| Intel® Xeon® Processor L5506 (2.13 GHz, 4MB L3 Cache, 60 Watts, DDR3-800) | 507678-B21 | |
| Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80 Watts, DDR3-800) | 505886-B21 | |
| Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80 Watts, DDR3-800) | 507682-B21 | |
| Intel® Xeon® Processor E5502 (1.86 GHz, 4MB L3 Cache, 80 Watts, DDR3-800) | 507663-B21 | |
| HP DL360G6 SFF HD Backplane Kit | 516966-B21 | |
| HP DL360 SL 12.7mm SATA DVD | 532066-B21 | |
| HP DL360 SL 12.7mm SATA DVD-RW Optical kit | 532068-B21 | |
| PCI-X Riser option NOTE: To convert full-length PCI-Express slot to PCI-X slot. | 518824-B21 | |
| | ||
| Processor | Quad-Core Processors | |
| Intel® Xeon® Processor X5570 (2.93 GHz,8MB L3 Cache, 95 Watts,DDR3-1333,HT Turbo 2/2/3/3) | 507674-B21 | |
| Intel® Xeon® Processor X5560 (2.80 GHz, 8MB L3 Cache, 95 Watts,DDR3-1333,HT Turbo 2/2/3/3) | 507676-B21 | |
| Intel® Xeon® Processor X5550 (2.66 GHz, 8MB L3 Cache, 95 Watts,DDR3-1333,HT Turbo 2/2/3/3) | 505878-B21 | |
| Intel® Xeon® Processor E5540 (2.53 GHz, 8MB L3 Cache, 80 Watts,DDR3-1066,HT Turbo 1/1/2/2) | 505880-B21 | |
| Intel® Xeon® Processor E5530 (2.40 GHz, 8MB L3 Cache, 80 Watts,DDR3-1066,HT Turbo 1/1/2/2) | 505882-B21 | |
| Intel® Xeon® Processor E5520 (2.26 GHz, 8MB L3 Cache, 60 Watts,DDR3-1066,HT Turbo 1/1/2/2) | 507680-B21 | |
| Intel® Xeon® Processor L5520 (2.26 GHz, 8MB L3 Cache, 80 Watts,DDR3-1066,HT Turbo 1/1/2/2) | 505884-B21 | |
| Intel® Xeon® Processor L5506 (2.13 GHz, 4MB L3 Cache, 60 Watts,DDR3-800) | 507678-B21 | |
| Intel® Xeon® Processor E5506 (2.13 GHz, 4MB L3 Cache, 80 Watts,DDR3-800) | 505886-B21 | |
| Intel® Xeon® Processor E5504 (2.00 GHz, 4MB L3 Cache, 80 Watts,DDR3-800) | 507682-B21 | |
| Dual-Core Processors | ||
| Intel® Xeon® Processor E5502 (1.86 GHz, 4MB L3 Cache, 80 Watts,DDR3-800) | 507663-B21 | |
| NOTE: Up to 2
processors supported. Performance Model configurations include two processors. NOTE: HT indicates that the processor model supports Intel® /Hyper-Threading Technology NOTE: Turbo indicates the maximum potential frequency increment when using Intel® Turbo Boost Technology, with 4,3,2 and 1 cores active. NOTE: DDR3 speed is the maximum memory speed of the processor. Actual memory speed may depend on the quantity and type of DIMMs installed. NOTE: For the Intel 5500 Series, the letter preceding the model number indicated the performance/wattage of the processor. "X" denotes High Performance/Wattage; "E" denotes Enterprise Performance/Wattage (Mainstream); and "L" denotes Lower Wattage. |
||
|
|
||
|
Memory |
Registered DIMMs (RDIMMs) | |
| HP 2GB 2Rx8 PC3-10600R-9 Kit |
500656-B21
|
|
| HP 4GB 2Rx4 PC3-10600R-9 Kit |
500658-B21
|
|
| HP 4GB 4Rx8 PC3-8500R-7 LP Kit |
500660-B21
|
|
| HP 8GB 2Rx4 PC3-8500R-7 Kit |
516423-B21
|
|
| HP 8GB 2Rx4 PC3-10600R-9 Kit | 500662-B21 | |
| Unbuffered with ECC DIMMs (UDIMMs) | ||
| HP 1GB 1Rx8 PC3-10600E-9 Kit | 500668-B21 | |
| HP 2GB 2Rx8 PC3-10600E-9 Kit | 500670-B21 | |
| NOTE: All DDR3
memory option kits consist of one DIMM per kit. For detailed memory configuration
rules and guidelines, please use the Online DDR3 Memory Configuration Tool:
www.hp.com/go/ddr3memory-configurator. NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient. |
||
|
|
||
|
Hot Plug HDD Backplane Option |
HP DL360G6 SFF HD Backplane Kit | 516966-B21 |
|
|
||
|
Optical Drives |
HP DL360 SL 12.7mm SATA DVD | 532066-B21 |
| HP DL360 SL 12.7mm SATA DVD-RW Optical kit | 532068-B21 | |
|
|
||
| Hard Drives | NOTE: Transfer rates of drives are dependent on the maximum transfer rate supported by the HBA or Controller. Refer to the HBA or Controller technical specifications for details. | |
| SAS Hot Plug SFF Enterprise (ENT) Drives | ||
| HP 300GB 6G SAS 10K SFF DP ENT HDD |
507127-B21
|
|
| HP 300GB 3G SAS 10K SFF DP ENT HDD |
492620-B21
|
|
| HP 146GB 6G SAS 10K SFF DP ENT HDD |
507125-B21
|
|
| HP 146GB 3G SAS 10K SFF DP ENT HDD |
418367-B21
|
|
| HP 146GB 3G SAS 15K SFF DP ENT HDD |
504062-B21
|
|
| HP 72GB 3G SAS 15K SFF DP ENT HDD |
418371-B21
|
|
| HP 72GB 3G SAS 10K SFF DP ENT HDD |
384842-B21
|
|
| HP 36GB 3G SAS 15K SFF DP ENT HDD |
418369-B21
|
|
| NOTE: SAS Enterprise drives have a 3 year warranty. Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12244_div/12244_div.html (Worldwide) | ||
| SATA Hot Plug SFF Entry (ETY) Drives | ||
| HP 250GB 3G SATA 5.4K SFF ETY HDD | 460355-B21 | |
| HP 120GB 1.5G SATA 5.4K SFF ETY HDD |
458924-B21
|
|
| NOTE: SATA drives
have a 1 year warranty. Please see the QuickSpecs for Technical Specifications
and additional information: http://h18000.www1.hp.com/products/quickspecs/13021_div/13021_div.html (Worldwide) |
||
|
|
||
| Communications | HP NC112T PCIe Gigabit Server Adapter |
503746-B21
|
| HP NC360T PCI Express Dual Port Gigabit Server Adapter |
412648-B21
|
|
| HP NC364T PCI Express Quad Port Gigabit Server Adapter |
435508-B21
|
|
| HP NC373F PCI Express Multifunction Gigabit Server Adapter |
394793-B21
|
|
| HP NC373T PCI Express Multifunction Gigabit Server Adapter |
394791-B21
|
|
| HP NC382T PCI Express Dual Port Multifunction Gigabit Server Adapter |
458492-B21
|
|
| HP NC522SFP Dual Port 10GbE Server
Adapter NOTE: A minimum of two gigabyte (2 GB) of server memory is required per each NC522SFP adapter. |
468332-B21
|
|
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: www.hp.com/go/ProLiantNICs |
|
| Redundant Options | CAUTION: Many HP ProLiant Servers now offer new power options, including Common Slot Power Supplies. These power supplies come in multiple power ratings and higher efficiency levels to offer the Right Size solution to fit your configuration. This provides improved power delivery and the advantage of reclaiming lost power. Prior to making a power supply selection it is "highly recommended" that the "HP Power Advisor" is run to determine the right size power supply for your server configuration. The HP Power Advisor is located at "www.hp.com/go/proliant-energy-efficient" In ProLiant Servers that have more than one power slot (bay), only same size power supplies are recommended. If non-matched power supplies are inserted you will get errors and operation will fail. | |
| HP 460W CS HE Power Supply Kit |
503296-B21 | |
| HP 750W CS HE Power Supply Kit |
512327-B21 | |
| HP 1200W CS HE Power Supply Kit |
500172-B21 | |
| NOTE:
Option Kits contain optional power supply, an IEC power cable and PDU IEC cables.
NOTE: For regional specific power cables please refer to Power Cable section below. | ||
| HP
PCI Thermal Power Kit NOTE: Supports 3rd Party Video Graphics cards. | 519254-B21 |
|
Содержание технического описания HP ProLiant DL360 Generation 6 |
Additional Options
| HP Insight Control Environment Suite | NOTE: Electronic licensing options are available for Insight Control suites software products. Please see the appropriate Insight Control QuickSpecs for additional information. www.hp.com/go/ice | |
| HP Insight Control suite | ||
| HP Insight Control suite, No Media 1-Server
License including 1 year of 24x7 Technical Support and Updates NOTE: This part number can be purchased as a single license or as multiple licenses with a single activation key. Customer will receive a license entitlement certificate via e-mail. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. Only available directly from HP and select resellers in the Americas region. |
452148-B22 | |
| HP Insight Software Media Kit NOTE: Insight Software DVD media without licenses. Contains Insight Manager and Essentials software products and components licensed by Insight Control Environment suite. Uses an integrated installer to perform quick and accurate software installation and updates. |
436222-B21 | |
| NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12631_div/12631_div.html | ||
| HP Insight Control Environment for Linux | ||
| HP Insight Control Environment for Linux,
Media pack (DVD) - No licenses included NOTE: This optional Media pack DVD contains the ISO image for HP Insight Control Environment for Linux, HP System Insight Manager, HP Insight Power Manager, HP Virtual Machine Management Pack, and an integrated installer. Servers must be acquired separately. NOTE: This Media pack is optional because the latest ISO image and latest updates may be downloaded at no cost from: http://www.hp.com/go/ice-linux (click on Download button). |
464422-B22
|
|
| HP Insight Control Environment for Linux,
No Media, 1-Server license, including one year of 24x7 Technical Support
and Updates NOTE: This part number can be used to purchase one (1) license with a single activation key. Customer will receive a printed license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. NOTE: One certificate is shipped for each license. |
464423-B22
|
|
| NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/13019_div/13019_div.html | ||
|
|
||
| Server Management Stand Alone Software Products | NOTE: Electronic licensing options are available for select software products. Please see the appropriate Insight Software standalone product QuickSpecs for additional information. | |
| Deploy | ||
| HP Insight Rapid Deployment software | ||
| HP Insight Rapid Deployment single license
including 1 yr 24x7 Technical Support and Updates NOTE: This license allows 1 server to be deployed and managed via RDP. Customer will receive a printed license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support Service |
452151-B21 | |
| NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11053_div/11053_div.html | ||
| HP Insight Server Migration software for ProLiant | ||
| HP Insight Server Migration software for
ProLiant, No Media, Physical / Virtual to ProLiant Single Migration License,
including 1 year of 24x7 Technical Support and Updates NOTE: This license allows 1 physical to ProLiant or virtual to ProLiant migration. Customer will receive a printed license entitlement certificate and documentation via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. |
460750-B21 | |
| HP Insight Server Migration software for
ProLiant, No Media, Physical / Virtual to Virtual Single Migration License,
including 1 year of 24x7 Technical Support and Updates NOTE: This license allows 1 physical to virtual or virtual to virtual migration. Customer will receive a printed license entitlement certificate and documentation via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. |
460753-B21 | |
| HP Insight Server Migration software for
ProLiant, No Media, 1-Year Unlimited Migration License, including 1 year
of 24x7 Technical Support NOTE: This license allows unlimited migrations (physical to ProLiant, physical to virtual, virtual to virtual, and virtual to ProLiant) for one year. Customer will receive a printed license entitlement certificate and documentation via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support Service. |
460756-B21 | |
| NOTE:
For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12855_div/12855_div.html |
||
| Monitor | ||
| HP Insight Dynamics-VSE suite for ProLiant | ||
| HP Insight Dynamics-VSE
with Insight Control Environment, 1-server license including 1 year of 24x7
Technical Support and Updates NOTE: This license supports HP ProLiant ML/DL and c-Class Blade servers. Customer will receive a printed license entitlement certificate via physical shipment. |
483527-B21 | |
| HP Insight Dynamics-VSE
without Insight Control Environment, 1-server license including 1 year of
24x7 Technical Support and Updates NOTE: This license supports HP ProLiant ML/DL and c-Class Blade servers. Customer will receive via email a receipt and link to a license entitlement certificate. |
483531-B21 | |
| NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/13050_div/13050_div.html | ||
| Control | ||
| Integrated Lights-Out Advanced Pack | ||
| HP Integrated Lights-Out Advanced Pack, No
Media, 1-Server License, including 1 year of 24x7 Technical Support and
Updates NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12362_div/12362_div.html |
512485-B21 | |
| Optimize | ||
| HP Insight Power Manager software (IPM) | ||
| HP Insight Power Manager software, No Media,
1-Server License, including 1 year of 24x7 Technical Support and Updates NOTE: Customers purchasing this upgrade must already have an iLO Advanced or Select license on each managed server. Customer will receive a printed license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. |
452677-B21 | |
| NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12623_div/12623_div.html | ||
| HP Virtual Machine Manager software for ProLiant | ||
| HP Virtual Machine Manager software for ProLiant,
No Media, 1-Server License, including 1 year of 24x7 Technical Support and
Updates NOTE: Customer will receive a printed license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. |
452153-B21 | |
| NOTE: For additional License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12328_div/12328_div.html | ||
| NOTE: Flexible and volume quantity license kits are available for Insight Software products. Refer to: http://www.hp.com/servers/proliantessentials or the various Insight Software QuickSpecs for more information. | ||
|
|
||
| Secure Digital (SD) Memory Cards | HP Photosmart 2GB Secure Digital (SD) Card |
L1877A
|
| HP Photosmart 4GB Secure Digital High Speed Card (SDHC) | L1878A#707 |
|
| Security | HP Trusted Platform Module Option Kit |
488069-B21
|
|
| Storage Controllers | SAS Controllers | |
| Smart Array P800 Controller | ||
| HP Smart Array P800/512 BBWC Controller | 381513-B21 | |
| Smart Array P212 Controller | ||
| HP Smart Array P212/Zero Memory Controller | 462828-B21 | |
| HP Smart Array P212/256 MB Controller | 462834-B21 | |
| 256 MB Cache | 462968-B21 | |
| Battery Kit upgrade (for BBWC) | 462969-B21 | |
| Smart Array P410i Controller Smart Array P410 Controller |
||
| HP Smart Array P410/256 MB Controller | 462862-B21 | |
| HP Smart Array P410/512 MB with BBWC Controller | 462864-B21 | |
| 512MB BBWC | 462967-B21 | |
| Battery Kit upgrade (for BBWC) | 462969-B21 | |
| Smart Array P411 Controller | ||
| HP Smart Array P411/256 MB Controller | 462830-B21 | |
| HP Smart Array P411/512 MB with BBWC Controller | 462832-B21 | |
| 512MB BBWC | 462967-B21 | |
| Battery Kit upgrade (for BBWC) | 462969-B21 | |
| NOTE:
Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12616_div/12616_div.html (Smart Array P800 Controller) http://h18000.www1.hp.com/products/quickspecs/13203_div/13203_div.html (Smart Array P212 Controller) http://h18000.www1.hp.com/products/quickspecs/13201_div/13201_div.html (Smart Array P410 Controller) http://h18000.www1.hp.com/products/quickspecs/13202_div/13202_div.html (Smart Array P411 Controller) |
||
| HP Smart Array Advanced Pack | ||
| HP Smart Array Advanced Pack No
Media 1-Server license including 1yr 24x7 Technical Support NOTE: This part number can be used to purchase a single license or to order multiple licenses with a single activation key. Customers will receive a license entitlement certificate via e-mail. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Include one year of 24x7 HP Software Technical Support Services. |
516471-B21 | |
| NOTE: Please see
the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/13200_div/13200_div.html |
||
| SAS Controller Options | ||
| SAS HBA | ||
| HP SC08Ge Host Bus Adapter NOTE: For use with additional 8 SFF drive cage (516914-B21). |
488765-B21 |
|
| NOTE:
Please see the QuickSpecs for Technical Specifications and additional
information: http://h18004.www1.hp.com/products/quickspecs/13082_div/13082_div.html (SC08Ge HBA) |
||
| SCSI HBA | ||
| HP SC11Xe Host Bus Adapter | 412911-B21 | |
| NOTE: Please see
the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/12566_div/12566_div.html (SC11Xe HBA) |
||
|
|
||
| Power Cords | NOTE: The HP ProLiant DL360 G6 ships with an IEC-IEC power cord used for rack mounting with Power Distribution Units (PDUs). | |
| Nema 5-15P to IEC320-C13 | AF556A | |
| Power Cord, Euro, 10A 250 V Straight (6 ft/1.83 m) |
AF568A
|
|
| Power Cord, UK, 10A 250 V Straight (6 ft/1.83 m) |
AF570A
|
|
| Power Cord, Danish, 10A 250 V Straight (6 ft/1.83 m) |
AF566A
|
|
| Power Cord, Swiss, 10A 250 V Straight (6 ft/1.83 m) |
AF565A
|
|
| Power Cord, Italian, 10A 250 V Straight (6 ft/1.83 m) |
AF571A
|
|
| Power Cord, South Africa, 10A 250 V Straight (8.2 ft/2.5 m) |
AF567A
|
|
| HPC Specific Options | HP IB 4X DDR PCI-e Dual Port HCA |
409376-B21 |
| HP IB 4X QDR PCI-e G2 Dual Port HCA | 517721-B21 | |
| HP IB 4X DDR Conn-X PCI-e G2 Dual Port HCA | 483514-B21 | |
| NOTE: Please see the QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/13078_div/13078_div.html. | |
| Tape Drives |
NOTE: For the complete listing of Tape Drive offerings, please
see: |
|
| USB Rack-Mount Tape Solutions | ||
| HP StorageWorks 1U USB Rack-Mount
Kit with one DAT 160 USB Tape Drive NOTE: Pre-configured with one DAT 160 USB tape drive. |
AG703A
|
|
| SAS Rack-Mount Tape Solutions NOTE: HP recommends purchasing the HP Smart Array P212 Controller (462828-B21) for a dedicated SAS HBA for tape. |
||
| HP StorageWorks 1U SAS Rack-Mount
Kit with one LTO-4 Ultrium 1760 NOTE: Pre-configured with one LTO-4 Ultrium 1760 SAS tape drive. |
EH946A
|
|
| HP StorageWorks 1U SAS Rack-Mount
Kit NOTE: Supports up to (2) half-height SAS tape drives. |
AE459A
|
|
| HP StorageWorks LTO-2 Ultrium
448 SAS Internal Tape Drive NOTE: Mounts inside the 1U SAS Rack-Mount Kit (AE459A). |
DW085A
|
|
| HP StorageWorks LTO-3 Ultrium
920 SAS Internal Tape Drive NOTE: Mounts inside the 1U SAS Rack-Mount Kit (AE459A). |
EH847A
|
|
| SCSI Rack-Mount Tape Solutions NOTE: SCSI Controller required. HP recommends purchasing the HP SC11Xe HBA (412911-B21) for a dedicated SCSI HBA for tape. |
||
| HP StorageWorks 1U Rack-mount kit with one Ultrium 448 (Carbonite) |
DW028B
|
|
| HP StorageWorks 1U SCSI Rack-mount kit with one Ultrium 920 |
EH903A
|
|
| NOTE: Please see
the Rack-Mount Tape Drive Kits QuickSpecs for additional information regarding
these kits: http://h18000.www1.hp.com/products/quickspecs/10854_div/10854_div.html (Worldwide) For an up-to-date listing of the latest O/S and software support details for HP tape drives, please visit: http://www.hp.com/go/connect. |
||
|
|
||
| Disk-Based Backup | RDX Removable Disk Backup | |
| HP StorageWorks
RDX160 External Removable Disk Backup System NOTE: 160GB of Disk Storage |
AJ766A
| |
| HP StorageWorks RDX320 External
Removable Disk Backup System NOTE: 320GB of Disk Storage |
AJ768A | |
| HP StorageWorks RDX500 External
Removable Disk Backup System NOTE: 500GB of Disk Storage |
AJ935A | |
| NOTE: Please see
the HP RDX Removable Disk Backup System QuickSpecs for additional information: http://h18000.www1.hp.com/products/quickspecs/13036_div/13036_div.html |
||
| D2D Backup | ||
| HP StorageWorks D2D120 Backup
System with Data Protector Express Software Kit NOTE: 2TB of Disk Storage |
EH924A
| |
| HP StorageWorks D2D130 Backup
System with LTO-3 Ultrium 920 SAS Tape Drive NOTE: 3TB of Disk Storage |
EH952A
| |
| HP StorageWorks D2D2503i Backup
System NOTE: 3TB of Disk Storage |
EH945A | |
| HP StorageWorks D2D4004i Backup
System NOTE: 4.5TB of Disk Storage |
EH938A | |
| NOTE: Please see the HP D2D Backup Systems QuickSpecs for additional information: http://www.hp.com/go/d2d | ||
| | ||
| Tape Autoloaders | HP StorageWorks DAT Autoloader | |
| HP StorageWorks DAT 72x10 tape autoloader | AE313B | |
| HP StorageWorks 1/8 G2 Tape Autoloader | ||
| HP StorageWorks 1/8 G2 LTO-4 Ultrium 1760 SAS Tape Autoloader | AK377A | |
| HP StorageWorks 1/8 G2 LTO-3 Ultrium 920 SAS Autoloader | AH558A | |
| HP StorageWorks 1/8 G2 LTO-2 Ultrium 448 Tape Autoloader | AH164A | |
| HP StorageWorks 1/8 G2 Tape Autoloader
Rack Kit NOTE: Required to install the 1/8 G2 Autoloaders in a standard 19-inch rack; includes rails and rackmount instructions. |
AH166A | |
| NOTE: Please reference the Tape Autoloader QuickSpecs at: http://www.hp.com/go/automation for additional information needed to create a complete solution. | ||
|
|
||
|
Tape Libraries |
HP StorageWorks MSL2024 Tape Library | |
| HP StorageWorks MSL2024 1 LTO-4 Ultrium 1840 SCSI Drive Library | AJ033A | |
| HP StorageWorks MSL2024 1 LTO-4 Ultrium 1760 SAS Drive Library | AK378A | |
| HP StorageWorks MSL2024 1 LTO-3 Ultrium 960 SCSI Drive Library | AG115A | |
| HP StorageWorks MSL2024 1 LTO-3 Ultrium 920 SAS Drive Library | AH559A | |
| HP StorageWorks MSL2024 1 LTO-2 Ultrium 448 SCSI Drive Library | AG116A | |
| HP StorageWorks MSL4048 Tape Library | ||
| HP StorageWorks MSL4048 1 LTO-4 Ultrium 1840 SCSI Drive Library | AJ035A | |
| HP StorageWorks MSL4048 2 LTO-4 Ultrium 1760 SAS Drive Library | AK380A | |
| HP StorageWorks MSL4048 1 LTO-3 Ultrium 960 SCSI Drive Library | AG322A | |
| HP StorageWorks MSL4048 1 LTO-3 Ultrium 920 SAS Drive Library | AH560A | |
| NOTE: Please reference the MSL Tape Library QuickSpecs at: http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at: http://www.hp.com/go/ebs. | ||
|
|
||
| High Availability Cluster Options | HP Serviceguard for Linux | |
| HP Serviceguard for Linux on HP
ProLiant and other third-party x86 Servers - Physical Media Kit NOTE: This kit contains media only. |
519353-B21
|
|
| HP Serviceguard for Linux on HP
ProLiant and other third-party x86 Servers Single-Server License Licensed per Server NOTE: This license allows Serviceguard for Linux to be installed on 1 server. Customer will receive a printed license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. |
519354-B21 | |
| HP Serviceguard for Linux - Flexible-Quantity
License (for HP ProLiant and other third-party x86 servers) Licensed per Server NOTE: This part number can be used to purchase multiple licenses with a single activation key. Customer will receive a printed license entitlement certificate via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service. |
519355-B21 | |
| HP Serviceguard Linux Oracle Database
Toolkit for HP ProLiant/x86 Servers Licensed per cluster Includes media and One Year 24x7 Software Support & Updates |
463833-B21
|
|
| HP Serviceguard Extension for
SAP on Linux for HP ProLiant/x86 Servers Licensed per physical server Includes media and One Year 24x7 Software Support & Updates |
463834-B21
|
|
| HP Serviceguard Linux Extended
Distance Cluster (XDC) for HP ProLiant/x86 Servers Licensed per physical server Includes media and One Year 24x7 Software Support & Updates |
463835-B21
|
|
| NOTE: The above
is not a complete list of all HP Serviceguard for Linux product numbers
For a detailed list of supported configuration/certification options for
HP Serviceguard for Linux please refer to the HP Serviceguard for Linux
Configuration & Ordering Guide available at: http://www.hp.com/go/sglx/info. NOTE: HP Serviceguard for Linux products running on x86 platforms now include one year of 24 x 7 Software Technical Support and Updates. Please see the Support Information section of the HP Serviceguard for Linux QuickSpecs for details. NOTE: For additional information including a complete list of Product Numbers for HP Serviceguard for Linux, please see the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11518_div/11518_div.html (Worldwide) |
||
|
|
||
| StorageWorks Options | StorageWorks Fibre Channel HBA | |
| NOTE: The following is a list of all Fibre Channel Host Bus Adapters for Windows and Linux. For detailed compatibility information please see: http://h18006.www1.hp.com/storage/saninfrastructure/hba.html | ||
| HP StorageWorks FC2142SR 4Gb PCI-e HBA | A8002A | |
| HP StorageWorks FC2242SR Dual Channel 4Gb PCI-e HBA |
A8003A | |
| HP StorageWorks FC1142SR 4Gb PCI-e HBA |
AE311A | |
| HP StorageWorks FC1242SR Dual Channel 4Gb PCI-e HBA |
AE312A | |
| HP StorageWorks 81Q PCI-e FC HBA |
AK344A | |
| HP StorageWorks 8Gb Simple SAN Connection Kit | AK241A | |
| HP StorageWorks 81E 8Gb PCI-e
FC HBA | AJ762A | |
| HP StorageWorks 82E 8Gb Dual-port
PCI-e FC HBA | AJ763A | |
| HP StorageWorks 82Q 8Gb Dual Port PCI-e FC HBA | AJ764A | |
| StorageWorks SCSI HBA | ||
| HP
U320e SCSI Host Bus Adapter NOTE: Recommended Dual Channel Ultra320 SCSI Controller for connecting multi-drive MSL tape libraries to ProLiant servers. |
AH627A | |
| | ||
|
HP StorageWorks 60 Modular Smart Array |
HP StorageWorks 60 Modular Smart Array |
418408-B21
|
| NOTE: Please see the QuickSpecs for additional options and configuration information at: http://h18000.www1.hp.com/products/quickspecs/12627_div/12627_div.html (Worldwide) | ||
| | ||
|
HP StorageWorks 70 Modular Smart Array |
HP StorageWorks 70 Modular Smart Array |
418800-B21
|
| NOTE: Please see the QuickSpecs for additional options and configuration information at: http://h18000.www1.hp.com/products/quickspecs/12652_div/12652_div.html (Worldwide) | ||
| | ||
|
HP StorageWorks 2000sa Modular Smart Array |
HP 2012sa Single Controller Modular Smart Array |
AJ752A
|
| HP 2012sa Dual Controller Modular Smart Array | AJ753A | |
| NOTE: Please see
the Modular Smart Array 2000sa QuickSpecs for additional options and configuration
information at: http://h18000.www1.hp.com/products/quickspecs/13045_div/13045_div.html (Worldwide) |
||
|
|
||
|
Uninterruptible Power Systems - Rack |
HP R1500 G2 UPS | |
| HP, R1.5kVA UPS, 1U, NA |
AF419A
|
|
| HP, R1.5kVA UPS, 1U, INTL |
AF418A
|
|
| HP, R1.5kVA UPS, 1U, JPN/TW |
AF421A
|
|
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12507_div/12507_div.html (Worldwide) | ||
| HP R3000 UPS | ||
| HP R3000 VA UPS, 2U, DTC, INTL |
AF414A
|
|
| HP R3000 VA UPS, 2U, Low voltage L5-30, NA | AF422A | |
| HP R3000 VA UPS, 2U, High voltage L6-20, NA | AF423A | |
| HP R3000 VA UPS, 2U, High voltage L6-20, JPN | AF424A | |
| HP R3000 VA UPS, 2U, Low voltage L5-30, JPN | AF425A | |
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/10671_div/10671_div.html (Worldwide) | ||
| HP R3000v Uninterruptible Power System | ||
| HP R3000v UPS NOTE: The R3000v is available in China and India only. |
AF444A | |
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13129_div/13129_div.html (Worldwide) | ||
| HP Rack-Mountable R5500 UPS | ||
| HP R5500 VA UPS, INTL | AF416A | |
| HP R5500 VA UPS, NA/JPN | AF426A | |
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/11871_div/11871_div.html (Worldwide) | ||
| NOTE: For additional information on HP Uninterruptable Power Systems please go to: www.hp.com/servers/rackups. | ||
|
|
||
|
HP Monitored Power Distribution Unit (PDU) |
HP Monitored Power Distribution Unit: Full Rack Version | |
| HP 17.3 kVA S2324 Monitored PDU- dual input, 3Ø, 24A (NA/JPN) |
AF503A
| |
| HP 8.6 kVA S1324 Monitored PDU- single input, 3Ø, 24A (NA/JPN) |
AF504A
| |
| HP 16.6 kVA S2140 Monitored PDU- dual input, 1Ø, 40A (NA/JPN) |
AF505A
| |
| HP 8.3 S1140 Monitored PDU- single input, 1Ø, 40A (NA/JPN) |
AF506A
| |
| HP 22.1 kVA S2316 Monitored PDU- dual input, 3Ø, 16A (INTL) |
AF507A
| |
| HP 11 kVA S1316 Monitored PDU- single input, 3Ø, 16A (INTL) |
AF508A
| |
| HP 14.7 kVA S2132 Monitored PDU- dual input, 1Ø, 32A (INTL) |
AF509A
| |
| HP 7.3 kVA S1132 Monitored PDU- single input, 1Ø, 32A (INTL) |
AF510A
| |
| HP Monitored Power Distribution Unit: Half Rack Version | ||
| HP 4.9 kVA S124 Monitored PDU- single input, 1Ø, 24A (NA/JPN) |
AF914A
| |
| HP 7.3 kVA S132 Monitored PDU- single input, 1Ø, 32A (INTL) |
AF915A
| |
| NOTE: Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12118_div/12118_div.html (Worldwide) | ||
|
| ||
| Modular
PDUs 1U/0U (Up to 32 outlets) NOTE: 1U/0U mounting brackets shipped with the unit (optimized for 10000 and 9000 series racks). |
Fixed Cord Extension Bars NOTE: Two extension bar sticks; each with (7) C13 plugs. |
351655-B21
|
| 3.6kVA Model - mPDU, 16A, High (WW) |
252663-B24
|
|
| 2.8 kVA Model - mPDU, 24A, Low (NA/JPN) |
252663-D71
|
|
| 4.9kVA Model - mPDU, 24A, High (NA/JPN) | 252663-D72 | |
| 7.3kVA Model - mPDU, 32A, High (INT'L) | 252663-B31 | |
| 8.3kVA Model - mPDU, 40A, High (WW) | 252663-B21 | |
| 8.3kVA Model - mPDU, 40A, High (power cord attached) (NA/JPN) | 252663-D73 | |
| 9.2kVA Model - mPDU, 40A, High (power cord attached) (INTL) | 252663-B32 | |
| 8.3kVA Model - mPDU 40A, High (core only) (NA/JPN) | 252663-D75 | |
| 9.2kVA Model - mPDU 40 A, High (core only) (Int'l) | 252663-B34 | |
| 8.3kVA Model - mPDU 32A, High (core only) (Int'l) | 252663-B33 | |
| 4.9kVA Model - mPDU 24A, High (core only) (NA/JPN) | 252663-D74 | |
| NOTE: For additional information on HP Power Distribution Units including accessories please go to: www.hp.com/go/pdu (Worldwide) | ||
|
|
||
| Rack Kits | 1U Cable Management Arm NOTE: Package contains two cable management arms. |
365403-B21
|
|
|
||
| USB Options | HP USB 2-Button Optical Scroll Mouse (Carbonite/Silver) |
DC172B
|
| USB 1.44-MB External Diskette Drive (Carbonite) |
DC141B
|
|
| HP USB 04 Standard Keyboard |
DT528A#ABA
|
|
|
|
||
| HP Rack 5000 Series
(Graphite Metallic) |
HP 5642 Rack Unassembled |
358254-B21
|
|
NOTE: Please see the QuickSpecs for Technical Specifications and
additional information: http://h18000.www1.hp.com/products/quickspecs/12074_div/12074_div.html
(Worldwide) |
||
| | ||
|
HP Rack 10000 G2 Series | 10642 G2 (42U) Rack Cabinet - Pallet |
AF001A |
| 10642 G2 (42U) Rack Cabinet - Shock Pallet |
AF002A | |
| 10642 G2 (42U) Rack Cabinet - Crated |
AF003A | |
| 10642 G2 (42U) Rack Cabinet, with Extension - Shock Pallet | AF004A | |
| 10636 G2 (36U) Rack Cabinet - Pallet | AF011A | |
| 10636 G2 (36U) Rack Cabinet - Shock Pallet | AF012A | |
| 10636 G2 (36U) Rack Cabinet - Crated | AF013A | |
| 10636 G2 (36U) Rack Cabinet, with Extension - Shock Pallet |
AF014A | |
| 10622 G2 (22U) Rack Cabinet - Pallet |
AF021A | |
| 10622 G2 (22U) Rack Cabinet - Shock Pallet |
AF022A | |
| 10642 G2 (42U) Rack Cabinet 1200mm Deep - Shock Pallet | AF034A | |
| 10642 G2 (42U) Rack Cabinet 1200mm Deep - Pallet | AF038A | |
| 10842 G2 (42U) 800mm Wide Rack Cabinet - Pallet |
AF041A | |
| 10842 G2 (42U) 800mm Wide Rack Cabinet - Shock Pallet |
AF042A | |
| 10647 G2 (47U) Rack Cabinet - Pallet |
AF031A | |
| HP Rack S10614 (14U) Rack Cabinet - Shock Pallet | 292302-B22 | |
| 10647 G2 (47U) Rack Cabinet 1200mm
Deep - Shock Pallet NOTE: Due to handling and shipping requirements, AF044A is only orderable through HP Factory Express. It is not for direct sales. Customer site surveys are required before an order is approved. CTO orders may require additional lead time. | AF044A | |
| 10647 G2 (47U) Rack Cabinet 1200mm Deep - Pallet | AF045A | |
| NOTE: It is mandatory
to use a shock pallet when shipping racks with equipment installed. NOTE: xxxxxx-B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels). | ||
| NOTE: Please
see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12402_div/12402_div.html (Worldwide) | ||
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. | ||
| | ||
| Keyboards and Monitors | TFT7600 Rackmount Keyboard Monitor US |
AG052A
|
| TFT7600 Rackmount Keyboard Monitor UK |
AG053A
|
|
| TFT7600 Rackmount Keyboard Monitor GR |
AG054A
|
|
| TFT7600 Rackmount Keyboard Monitor FR |
AG055A
|
|
| TFT7600 Rackmount Keyboard Monitor IT |
AG056A
|
|
| TFT7600 Rackmount Keyboard Monitor SP |
AG057A
|
|
| TFT7600 Rackmount Keyboard Monitor DEN |
AG058A
|
|
| TFT7600 Rackmount Keyboard Monitor NOR |
AG059A
|
|
| TFT7600 Rackmount Keyboard Monitor SE/FI |
AG060A
|
|
| TFT7600 Rackmount Keyboard Monitor SWI |
AG061A
|
|
| TFT7600 Rackmount Keyboard Monitor PORT |
AG062A
|
|
| TFT7600 Rackmount Keyboard Monitor BEL |
AG063A
|
|
| TFT7600 Rackmount Keyboard Monitor JPN2 |
AG064A
|
|
| TFT7600 Rackmount Keyboard Monitor RUS |
AG065A
|
|
| TFT7600 Rackmount Keyboard Monitor INTL |
AG066A
|
|
| 1U Rackmount Keyboard with USB, US |
AG072A
|
|
| 1U Rackmount Keyboard with USB, UK |
AG073A
|
|
| 1U Rackmount Keyboard with USB, GR |
AG074A
|
|
| 1U Rackmount Keyboard with USB, FR |
AG075A
|
|
| 1U Rackmount Keyboard with USB, ITL |
AG076A
|
|
| 1U Rackmount Keyboard with USB, SP |
AG077A
|
|
| 1U Rackmount Keyboard with USB, DEN |
AG078A
|
|
| 1U Rackmount Keyboard with USB, NOR |
AG079A
|
|
| 1U Rackmount Keyboard with USB, SE/FI |
AG080A
|
|
| 1U Rackmount Keyboard with USB, SWI |
AG081A
|
|
| 1U Rackmount Keyboard with USB, PORT |
AG082A
|
|
| 1U Rackmount Keyboard with USB, BEL |
AG083A
|
|
| 1U Rackmount Keyboard with USB, JPN2 |
AG084A
|
|
| 1U Rackmount Keyboard with USB, RUS |
AG085A
|
|
| 1U Rackmount Keyboard with USB, INTL |
AG086A
|
|
| NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://www.hp.com/go/rackandpower. | ||
|
|
||
| HP KVM Switch Options | 2x1x16 IP Console Switch with Virtual Media |
AF601A
|
| 4x1x16 IP Console Switch with Virtual Media |
AF602A
|
|
| 2x16 Server Console Switch with Virtual Media |
AF600A
|
|
| PS/2 Virtual Media Interface Adapter,
1 pack NOTE: Requires PS/2 and one USB port on server. |
AF604A
|
|
| Server console switch 0x2x8 |
AF616A
|
|
| Server console switch 0x2x16 |
AF617A
|
|
| PS/2 Interface Adapter, 1 pack |
262588-B21
|
|
| PS/2 Interface Adapter, 8 pack |
262587-B21
|
|
| NOTE: Cat5e cables are required to connect Interface Adapters to Console Switches. Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. | ||
| HP 1x4 Console Switch (ALL) |
AF611A
|
|
| PS2 Server Console Cable, 6 ft, 2 pack |
AF612A
|
|
| USB Server Console Cable, 6 ft, 2 pack |
AF613A
|
|
| NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. | ||
|
|
||
| HP Serial Console Server Options | HP 16 Port Serial Console Server (worldwide) |
AF101A
|
| HP 48 Port Serial Console Server (worldwide) |
AF102A
|
|
| Serial Adapter, RJ45-DB9 DCE Female, 1 Pack |
AF103A
|
|
| Serial Adapter, RJ45-DB9 DCE Female, 8 Pack |
AF110A
|
|
| NOTE: Cat5e cables are required to connect Serial Adapters to Serial Console Servers. Additional Serial Adapters and Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm. | ||
| NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm. | ||
|
|
||
| Service
and Support Offerings (HP Care Pack Services) |
Hardware Services 4-Hour On-site Service | |
| 4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic |
U4496E
|
|
| 4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic |
U4497E
|
|
| Hardware Services 6-Hour Call to Repair On-site Service | ||
|
6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic |
U4498E
|
|
| Hardware Services Next Business Day On-Site Service | ||
| Hardware Installation, Electronic |
U4506E
|
|
| Installation & Start-Up of a ProLiant server and Microsoft or Linux O/S per the Customer Description and/or Data Sheet. To be delivered on a scheduled basis 8am-5pm, M-F, excl. HP holidays, Electronic |
U4507E
|
|
| Support Plus | ||
| Onsite HW support, 8am-9pm, M-F, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays, Electronic |
U4508E
|
|
| Support Plus 24 | ||
| Onsite HW support 24x7, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic |
U4509E
|
|
| Onsite HW support 24x7, 4hr response and SuSE Linux SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic |
U6310E
|
|
| Onsite HW support 24x7, 4hr response and Red Hat ES Linux SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic |
U8332E
|
|
| NOTE: For more information, customer/resellers can contact: http://www.hp.com/services/carepack. |
|
Содержание технического описания HP ProLiant DL360 Generation 6 |
Memory
| NOTE: Memory configurations listed do not apply to "Factory Integrated Models". |
| DDR3
memory population guidelines
|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
NOTES:
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
DIMM slot and configuration diagrams
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Standard memory configuration (1 CPU model)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Standard memory plus optional memory (1 CPU model)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Standard memory replaced
with optional memory (1 CPU model)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| UDIMM maximum configuration (1 CPU model)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Standard memory replaced
with optional memory (2 CPU model)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| UDIMM maximum configuration (2 CPU model)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| NOTE: Capacity references are rounded to the common Gigabyte values.
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Following are memory options available from HP: | ||
| Memory | Registered DIMMs (RDIMMs) | |
| HP 2GB 2Rx8 PC3-10600R-9 Kit | 500656-B21 | |
| HP 4GB 2Rx4 PC3-10600R-9 Kit | 500658-B21 | |
| HP 4GB 4Rx8 PC3-8500R-7 LP Kit | 500660-B21 | |
| HP 8GB 2Rx4 PC3-8500R-7 Kit | 516423-B21 | |
| HP 8GB 2Rx4 PC3-10600R-9 Kit | 500662-B21 | |
| Unbuffered with ECC DIMMs (UDIMMs) | ||
| HP 1GB 1Rx8 PC3-10600E-9 Kit | 500668-B21 | |
| HP 2GB 2Rx8 PC3-10600E-9 Kit | 500670-B21 | |
| NOTE: All DDR3
memory option kits consist of one DIMM per kit. For detailed memory configuration
rules and guidelines, please use the Online DDR3 Memory Configuration Tool:
www.hp.com/go/ddr3memory-configurator. NOTE: Kits described as LP include Low Power DIMMs. For more information on ProLiant Energy Efficient Features, see: www.hp.com/go/proliant-energy-efficient |
||
|
Содержание технического описания HP ProLiant DL360 Generation 6 |
Storage
![]() |
1-8
|
8 x SFF SAS Hot Pluggable Hard Drive Bays. Optical Media Bay not available for this configuration |
![]() |
1-4 | 4 x SFF SAS Hot Pluggable Hard Drives |
| A | Optical Media Bay | |
| 5, 6 | Blanks (HDD Bays will not function) |
|
Drive Support |
|||
|
|
|||
|
Quantity |
Position |
Controller |
|
|
Removable Media |
|||
| HP DL360 SL 12.7mm SATA DVD-RW |
1
|
Slime Line Bay
|
Integrated SATA |
| HP DL360 SL 12.7mm SATA DVD |
1
|
Slime Line Bay
|
Integrated SATA |
|
|
|||
|
Hard Drives NOTE: Transfer rates of drives are dependent on the maximum transfer rate supported by the HBA or Controller. Refer to the HBA or Controller technical specifications for details. | |||
| SAS Hot Plug SFF Enterprise (ENT) Drives | |||
| Quantity Supported |
Position Supported | Controller | |
| 300GB 3G
SAS 10K DP 300GB 6G SAS 10K DP 146GB 6G SAS 10K DP 146GB 15K 2.5 SAS DP 146GB 3G SAS 10K SP 146GB 3G SAS 10K DP 72GB 3G SAS 10K SP 72GB 3G SAS 10K DP 72GB 3G SAS 15K SP 72GB 3G SAS 15K DP 36GB 3G SAS 15K SP 36GB 3G SAS 15K DP |
8 |
1-8 |
HP Smart Array P212/Zero Memory Controller HP Smart Array P212/256 MB Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
| | |||
| SATA Hot Plug Entry (ETY) Drives | |||
|
Quantity Supported |
Position Supported | Controller | |
| 250GB 3G
SATA 5.4K 120GB 1.5G SATA 5.4K |
8 |
1-8 | HP
Smart Array P212/Zero Memory Controller HP Smart Array P212/256 MB Controller HP Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller |
| | |||
|
External Storage | |||
| Quantity |
Position |
Host Controller or Adapter | |
| 60 Modular Smart Array |
Up to 4 |
External | HP
Smart Array P212/Zero Memory Controller HP Smart Array P212/256 MB Controller |
| Up
to 8 | External | HP
Smart Array P411/256 MB Controller HP Smart Array P411/512 MB BBWC Controller | |
| 70 Modular Smart Array | Up
to 2 | External | HP
Smart Array P212/Zero Memory Controller HP Smart Array P212/256 MB Controller |
| Up
to 4 | External | HP Smart Array P411/256 MB Controller | |
| HP 2000sa Modular Smart Array Controller | Up to 4 | External | HP SC08Ge Host Bus Adapter |
|
| |||
| Tape and Disk-Based Backup | |||
| NOTE: For a complete listing of compatible tape and disk-based backup offerings, please visit: www.hp.com/go/connect. |
|
Position Supported |
Controller |
Part Number | |
| HP
StorageWorks SCSI Tape Drives, External LTO-1 Ultrium 232 LTO-2 Ultrium 448 LTO-3 Ultrium 960 LTO-3 Ultrium 920 LTO-4 Ultrium 1760 LTO-4 Ultrium 1840 DAT 40 DAT 72 DAT 160 1U Rack-Mount Kit 3U Rack-Mount Kit | External | HP SC11Xe Host Bus Adapter |
412911-B21 |
| HP StorageWorks USB Tape Drives,
External DAT 40 USB DAT 72 USB DAT 160 USB 1U Rack-Mount Kit | External | USB 2.0 Port | N/A |
| HP
StorageWorks SAS Tape Drives, External DAT 160 SAS LTO-2 Ultrium 448 SAS LTO-3 Ultrium 920 SAS LTO-4 Ultrium 1760 SAS LTO-4 Ultrium 1840 SAS 1U Rack-Mount Kit |
External | HP Smart Array P212/Zero Memory Controller |
462828-B21 |
| HP
StorageWorks SCSI Tape Automation, External DAT 72x10 Autoloader 1/8 G2 Autoloader MSL2024 MSL4048 MSL8096 MSL6000 |
External | HP SC11Xe Host Bus Adapter |
412911-B21 |
| HP
U320e SCSI Host Bus Adapter NOTE: Recommended for MSL tape libraries. |
AH627A | ||
| HP
StorageWorks SAS Tape Automation, External 1/8 G2 Autoloader MSL2024 MSL4048 MSL8096 |
External | HP Smart Array P212/Zero Memory Controller |
462828-B21 |
| HP
StorageWorks Fibre Tape Automation, External MSL2024 MSL4048 MSL8096 MSL6000 | External | Please consult the EBS connectivity matrix at: http://www.hp.com/go/ebs for detailed connectivity information. |
N/A |
| HP
StorageWorks RDX Removable Disk Backup System RDX160 RDX320 RDX500 | External | USB 2.0 Port | N/A |
| HP StorageWorks D2D Backup Systems
D2D120 D2D130 D2D2503i D2D4004i |
External | Embedded Network Controller |
N/A |
|
Содержание технического описания HP ProLiant DL360 Generation 6 |
Power Specifications
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Optional Power Supplies | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| To review typical system power ratings use the HP Power Advisor which is available via the online tool located at URL: www.hp.com/go/proliant-energy-efficient or www.hp.com/go/hppoweradvisor |
|
Содержание технического описания HP ProLiant DL360 Generation 6 |
Technical Specifications
| System Unit | Dimensions
(H x W x D) (with bezel) | 1.70 x 16.78 x 27.25 in (4.32 x 42.62 x 69.22 cm) | |
|
Weight (approximate) | Maximum (all hard drives, power supplies, and processors installed) | 39.5 lb (17.92 kg) | |
| Minimum
(one hard drive, power supply, and processor installed) | 32 lb (14.51 kg) | ||
|
Input Requirements (for Standard 460W PSU, see power specifications tables for detail on 460W, 750W and 1200W power supplies) | Rated Line Voltage | 100 to 240 VAC | |
| Rated Input Current | 4.5 Amps (at 120VAC) to 2.2 Amps (at 240 VAC) | ||
| Rated Input Frequency | 50 to 60 Hz | ||
| BTU Rating | Maximum | 1773 BTU / hr (at 120 VAC), 1715 (at 240 VAC) | |
| Power Specifications | To
review typical system power ratings use the HP Power Advisor which is available
via the online tool located at URL: www.hp.com/go/proliant-energy-efficient
or www.hp.com/go/hppoweradvisor
- Click on the system of interest. Example: DL360 G6 - Follow the instructions of the next screens. | ||
| Power
Supply Output (per power supply) | Rated Steady-State Power | 460 W (at
100 VAC), 460 W (at 200 VAC) | |
| Maximum Peak Power | 460 W (at 100 VAC), 460 W (at 200 VAC) NOTE: See Power Supply Specifications tables for complete details on 460W PSU and optional 750W and 1200W Power Supply Options. | ||
| System Inlet Temperature | Operating | 10°
to 35° C (50° to 95° F) at sea level with an altitude derating of
1.0°C per every 305 m (1.8° F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct sustained sunlight. Maximum rate of change
is 10° C/hr (18° F/hr). The upper limit may be limited by the type and
number of options installed. System performance may be reduced if operating with a fan fault or above 30° C (86° F). | |
| Non-operating | -40° to 70° C (-40° to 158° F). Maximum rate of change is 20° C/hr (36° F/hr). | ||
| Relative
Humidity (non-condensing) | Operating | 10 to 90% relative humidity (Rh), 28° C (82.4° F) maximum wet bulb temperature, non-condensing. | |
| Non-operating | 5 to 95% relative humidity (Rh), 38.7° C (101.7° F) maximum wet bulb temperature, non-condensing. | ||
| Altitude | Operating | 3050 m (10,000 ft). This value may be limited by the type and number of options installed. Maximum allowable altitude change rate is 457 m/min (1500 ft/min). | |
| Non-operating | 9144 m (30,000 ft). Maximum allowable altitude change rate is 457 m/min (1500 ft/min). | ||
| Acoustic Noise | Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted sound pressure levels (LpAm) when the product is operating in a 23° C ambient environment. Noise emissions were measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109). | ||
| Idle | |||
| L WAd | 6.4 B | ||
| L
pAm | 49 dBA | ||
| Operating | |||
| L WAd | 6.4 B | ||
| L
pAm | 49 dBA | ||
| Emissions Classification (EMC) | FCC Rating | Class A | |
| Normative Standards | CISPR 22; EN55022; EN55024; FCC CFR 47, Pt 15; ICES-003; CNS13438; GB9254; K22; K24; EN 61000-3-2; EN 61000-3-3; EN 60950-1; IEC 60950-1 | ||
| NOTE: Product conformance to cited product specifications is based on sample (type) testing, evaluation, or assessment. This product or family of products is eligible to bear the appropriate compliance logos and statements. | |||
|
| |||
|
Smart Array P410i Controller |
Dimensions (not including bracket) |
Low Profile PCIe Form Factor 7.5 in x 9.5 in x 2.25 in (19.05 cm x 24.13 cm x 5.72 cm) |
| Disk Drive and Enclosure Interface - Transfer rate | 3G SAS (Serial Attached SCSI)/6G SAS Capable | |
| 1.5G SATA (Serial ATA)/3G SATA Capable | ||
| SAS Connectors | 2 internal (Mini-SAS) x8 wide port connectors | |
| Cache Memory Speed | DDR2-800MHz with 40 or 72-bit wide bus provides up to 4.2 GB/s maximum bandwidth. | |
| Server Interface | x8 5G PCIe 2.0 provides 4GB/s maximum bandwidth | |
| SAS Speed | x8 3G SAS provides 2.4GB/s maximum bandwidth | |
| Cache Memory | 40-bit 256MB ECC protected cache (72-bit 512MB BBWC module upgrades available); transportable with battery-backed upgrade | |
| Logical Drives Supported | Up to 12 logical drives | |
| Maximum Logical Drive Capacity | Greater than 2TB | |
| Host Memory Addressing | 64-bit, supporting greater than 4GB server memory space | |
| RAID Support | RAID 6, 6+0 (Advanced Data Guarding) NOTE: The minimum of 256 MB cache, battery kit, and Smart Array Advanced Pack License Key upgrade is required to enable RAID 6, 6+0 |
|
| RAID 5, 5+0 (Distributed Data
Guarding) NOTE: The 256MB upgrade is required to enable RAID 5 support on the Smart Array P410i. |
||
| RAID 1+0 (Striping & Mirroring) | ||
| RAID 0 (Striping) | ||
| Upgradeable Firmware | Upgradeable Firmware with recovery ROM feature | |
|
|
||
| Embedded NC382i Dual Port Multifunction Gigabit Server Adapter | Network Interface | 10Base-T/100Base-TX/1000Base-TX | |
| Compatibility | IEEE 802.3 10Base-T | ||
| IEEE 802.3ab 1000Base-T | |||
| IEEE 802.3u 100Base-TX | |||
| IEEE 802.3ad 1000Base-TX | |||
| IEEE 802.1p 100Base-TX | |||
| IEEE 802.1q 100Base-TX | |||
| Data Transfer Method | PCI Express, four lanes (x4) | ||
| Network Transfer Rate | 10Base-T (Half-Duplex) | 10 Mb/s | |
| 10Base-T (Full-Duplex) | 20 Mb/s | ||
| 100Base-TX (Half-Duplex) | 100 Mb/s | ||
| 100Base-TX (Full-Duplex) | 200 Mb/s | ||
| 1000Base-TX (Half and Full-Duplex) | 2000 Mb/s | ||
| Connector | Two RJ-45 | ||
| Cable Support | 10Base-T | Categories 3, 4 or 5 UTP; up to 328 ft (100 m) | |
| 100Base-TX | Category 5 or higher UTP; up to 328 ft (100 m) | ||
| 1000BaseTX | Category 5 or higher UTP; up to 328 ft (100 m) | ||
|
|
|||
| Environment-friendly Products and Approach | End-of-life Management and Recycling |
Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling
programs in many geographic areas. For trade-in information, please go
to: http://www.hp.com/go/green.
To recycle your product, please go to: http://www.hp.com/go/green
or contact your nearest HP sales office. Products returned to HP will
be recycled, recovered or disposed of in a responsible manner. |
| | ||
|
© Copyright 2009 Hewlett-Packard Development Company,
L.P. |
 DA-13235 6 - Version 6 - May 21, 2009
Вопросы и ответы
Оцените новый конфигуратор серверов
Доcтаточно просто нажать на выбранный вами пункт!Перейти к списку доступных для конфигурирования моделей
Удобно и адекватные цены
Удобно, но цены кусаются
Использую для сравнения, но покупать не буду
Собираю конфигурации на других сайтах
Хотелось бы видеть цены сразу
Акции
Компания Server Unit предлагает позиции своего склада по сниженным ценам.
Новости
- Новый сертификат от APC
- Новинка: Dell PowerEdge C6145
- Новая услуга "Сервер Эксперт"
- Eset начинает бета-тестирование NOD32 для Lotus Domino
- StorСenter ix2 Network Storage от Iomega
- Наши клиенты: ОАО "Гайский ГОК"
- Самый тонкий в мире ультрабук
- Компания Seagate приобрела подразделение у Samsung
- 75 новых ультрабуков в 2012 году
- Наши новые клиенты: ОАО ГАК "ОБОРОНПРОМКОМПЛЕКС"