1. Redundant Cooling 650W
Power Supply
2. 7x 3.5" SAS / SATA Hot-swappable
Drive Bays
3. 3x 5.25" Peripheral Drive Bays
4. 1x 5.25" Drive Bay for 3.5"
1.44MB Floppy Drive
5. 7x Full-height, Full-length
expansion slot
6. 2x 90mm Hot-swappable Fan
7. 1x 12cm Rear-exhaust Fan
8. 2x Front USB Ports (optional)
9. Locking Bezel
10. Power / Reset Switch &
6 LED Indicators
| Product SKUs | |
| CSE-742T-650 |
|
| CSE-742T-650B |
|
| Form Factor | ||
| 4U chassis support for max. motherboard size - 12" x 13" E-ATX | ||
| Processor Support | ||
| Dual Xeon® Processors | ||
| Dimensions | ||
| Height | 7.0" (178mm) | |
| Width | 17.8" (452mm) | |
| Depth | 23.8" (605mm) | |
| Gross Weight | 49 lbs (22.2kg) | |
| Available Colors | Beige, Black | |
| Expansion Slots | ||
| 7x PCI expansion slots | ||
| Drive Bays | ||
| Hot-swap |
7x 3.5" SAS / SATA Hot-swap Drive Bays SAS or enterprise SATA HDD only recommended |
|
| Peripheral Bay(s) |
3x 5.25" Peripheral Drive Bay 1x 5.25" Bay For Floppy Drive |
|
| SATA Backplane | ||
| 7 x 3.5" SATA Backplane | ||
| Front Panel | ||
| Buttons |
Power On/Off button System Reset button NMI Switch |
|
| LEDs |
Power LED Hard drive activity LED 2x Network activity LEDs System Overheat LED Power Fail LED |
|
| Ports | none | |
| System Cooling | ||
| Fans |
2x 9cm Hot-swappable Fans 1x 12cm Rear Exhaust Fan |
|
| System Monitoring | ||
| Chassis intrusion switch | ||
| Operating Environment (System) | ||
| Operating Temperature Range | 10° - 35°C (50° to 95° F) | |
| Non-Operating Temperature Range | -40° - +70°C (-40° to 158° F) | |
| Humidity Range | 8 - 90% non-condensing | |
| Non-Operating Humidity Range | 5 - 95% non-condensing | |
| Power Supply | ||
| 650W Redundant-cooling AC power supply with PFC [ 24-pin, (4-pin, 8-pin) = 12V ] |
||
| AC Voltage | 100 - 240V, 47-63Hz, 11 - 5 Amp | |
| DC Output | 5V + 3.3V ≤ 160W | |
| +5V | 30.0 amp | |
| +5V standby | 4.0 amp | |
| +12V | 46.0amp | |
| -12V | 0.6 amp | |
| +3.3V | 30.0 amp | |
| Regulatory (Power Supply) | ||
| Power Supply Safety / EMC | USA - UL listed, FCC Canada - CUL listed Germany - TUV Certified Europe/CE Mark EN 60950/IEC 60950-Compliant |
|
|
|||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||
| IBM X3550 | 3 | |
| IBM X3650 | 4 |
| PowerEdge R610 | 6 | |
| PowerEdge R710 | 11 |
| ProLiant DL 120 G7 | 2 | |
| ProLiant DL 320 G6 | 2 | |
| ProLiant DL 160 G6 | 2 | |
| ProLiant DL 360 G6 | 2 | |
| ProLiant DL 380 G5 | 2 | |
| ProLiant DL 380 G5 | 1 | |
| ProLiant DL 380 G7 | 10 | |
| ProLiant ML 350 G6 | 2 | |